APP3Y1544T - EC-15T
During heavy use or sand blasting, we recommend using the continuous run feature. If you follow the ¼”
copper line that runs across the cylinder heads down to the tank you will find the red handle ¼” Ball valve,
it will be in the open position, this is the continuous run. To close this, turn the handle to the start/stop
position. Some will have a thumbscrew turn completely out for continuous run, run all the way in for stop-
start mode.
ALWAYS PULL THE MOTOR DISCONNECT SWITCH BEFORE WORKING ON BELTS SO THE
MOTOR CANNOT START UP UNEXPECTEDLY.
When belt tension is adjusted properly, the belts can be
depressed at a point midway between the motor pulley and the flywheel approximately one half of an inch.
Loose belts will slip on the motor pulley and cause undue heating and wear. A belt that is too tight will
overload the bearings. Adjustments can be made by sliding the motor along its base. When installing new
belts, it is necessary that the motor bolts be loosened and the motor be moved toward the compressor.
The new belts can then be installed without damage or strain. As belts will stretch, it is recommended that
all belts be changed at the same time.
¼” Copper tubing that runs across the cylinder heads will not be hooked up. This is for the continuous run.
You must have a pilot valve to utilize the continuous run feature.
Operation and Care
Continuous Run
All units are shipped with break-In Oil. Oil should be changed within the first 50 hours or 30 days,
which ever comes first. Use a mobile Rarus 427 available through your dealer or any non-detergent air
compressor oil.
WARNING
!!-Under
NO
circumstance should you use AUTOMOTIVE TYPE OIL. REPEAT-
DO NOT USE
AUTOMOTIVE TYPEOIL.
A. Check the oil level before starting.
B. Turn compressor over a few revolutions by hand to make sure that everything is free.
C. Check tension of the belts.
D. Remove tools, rags, and any other objects from the vicinity of the compressor.
E. Never put hands on the belts of idle units unless main motor switch is off.
F. Note the direction of the arrow on the flywheel and be sure that the direction of rotation is correct
when the machine is started. Correct direction is counterclockwise when standing facing the
flywheel. Air should be drawn through the intercooler onto the cylinders for maximumcooling.
Starting
Service
Bare Pumps
Belt Adjustment
4
• Oil should be changed every 90 days. Oil level should be at halfway level in sight lass.
• If oil is milky, oil should be changed!
• Inspect air filters weekly and change as needed.
Содержание POLAR AIR P01PSXXP10V120V208X
Страница 1: ...Polar Air Electric Operated Piston Compressors 1...
Страница 32: ......
Страница 39: ......
Страница 40: ......