APP3Y1544T - EC-15T
In order to receive maximum performance and long life from your compressor, the following instructions
should be carefully read and all points regarding installation and operation of the unit should be noted and
observed. A careful reading of this manual, prior to connecting anything to the motor of the compressor, will
pay dividends in terms of trouble-free operation.
Select a clean, dry, and well-lit location. In cold climates, the compressor should be installed in a heated
building. Insulate cold water or other low temperature pipes that pass overhead to avoid the possible collection
and dripping of condensate onto the compressor and motor that could cause rusting and/or motor shorting.
Do not install the compressor in a boiler room, paint spray room, or area where sandblasting is carried on. If
air in the area where the compressor is to be installed is acid or dust laden, the compressor intake should be
piped to the outside. This intake pipe should be increased one pipe size for every twenty (20) feet of run and
the intake filters should be installed at the end of the pipes with a hood to protect them from the elements.
Special size filters are required for pipe away.
If the compressor has to be located where the motor will be exposed to appreciable quantities of water, oil,
dirt, acid, or alkaline fumes, the motor must be of special construction to avoid rapid deterioration; i.e.TEFC.
Unless base is exactly level, shims will probably be required. Any space between base and foot should be
shimmed rather than drawing foot down thus placing strain on the unit. When unit is properly shimmed,
vibration will be at a minimum.
Allow sufficient space around the compressor so that it is accessible from all sides for maintenance. Mount
the unit with pulley side toward the wall, but at least 18 inches from it..
Check for possible damage in transit and see that the pulley turns freely by hand.
Report any damage to
the delivery carrier at once.
Introduction
Power Supply Andwiring
Inspection
Location
•
Connection should be made by a licensed electrician.
• Never connect power source to pressure switch.
• Power source is connected at the magnetic starter.
• A magnetic starter is required if not already part of the unit.
• ALL electrical connections must be checked for tightness before starting. This includes
connections at the motor junction as well as the starter.
This shall include all factory
connections.
Repeat: All electrical connections must be checked before startup.
The wiring should be done by a licensed electrician who is familiar with the requirements of the National
Board of Fire Underwriters and of the local inspectors. Consult your local electrical contractor electrical
codes for recommended wire sizes.