level exceeds the limit, the atomizer can not produce fog or spray column with a
small amount of fog.
The local water quality, environment, maintenance and other factors will directly
affect the life of atomizer, the working life of atomized ceramic wafers is
generally about 5,000 hours. When the atomizer runs for a long time, the spray
amount is reduced or only the spray column is used, and some holes do not even
produce fog, it is necessary to clean the water tank, or to replace a new atomizer
or atomized ceramic wafers (energy exchange wafers).
The replacing method of atomizing plate is as follow, see fig 11
图
11 Fig 11
Operation as following
a) Cut off the power, drain the water from the tank and dry the water on the
surface of the atomizer.
b) Unscrew the pressure ring with the lock piece, remove the old atomizer chip,
and keep the atomizer chamber clean.
c) When install the new atomizer chip’s front face up, and reverse side back
down. Then tighten the pressure ring
Special tips:
When the water level 0.1-0.5cm higher than the atomizer’s inductor,
the atomizer in the best working status. If the water level is too high or too low,
the fog outlet capacity will be affected.