GT610/GT620 Series High Performance Servo Driver User Manual
- 60 -
F0-09
Run command
channel
selection
0: Operation keyboard run command
channel
1: Terminal run command channel
2: Communication run command
channel
1
1
×
Run command channel selection is for enable source selection, which is set
according to user requirements.
When F0-09 is set to 0, run command is assigned by RUN;
When F0-09 is set to 1, run command is assigned via terminals (DI1
~
DI8 and
COM);
When F0-09 is set to 2, run command is assigned via terminal communication
,
which is host computer assignment.
F0-10
Shutdown
mode
0: Deceleration stop
1: Free stop
1
0
○
When F0-10 is set to 0, driver will carry out deceleration stop according to the set
deceleration time after receiving stop command, and its deceleration time is the
set value of F3-01;
When F0-10 is set to 1
,
after the driver receives a stop command, it will stop
output immediately, and the motor will stop after rotating according to load inertia
freely for a period of time.
F0-11
Over-voltage
stalling
protection
0: Off
1: On
1
1
×
This parameter is used together with F0-22, please combine F0-22 parameter
instructions for details
。
0: Off
,
over-voltage stalling protection does not function.
1: On
,
turn on over-voltage stalling protection function.