GT610/GT620 Series High Performance Servo Driver User Manual
- 48 -
Functio
n Code
Name
Setting Scope
Min.
Unit
Factory
Settings
Modification
Restriction
F6-03
AI1 terminal after
switching corresponds
to max. rotation speed
-100.0%
~
100.0%
0.1
%
25.0%
○
F6-04
AI1 input filtering time 0.00S
~
10.00s
0.01S
0.10S
○
F6-05
AI1 input gain
0.01%
~
600.00%
1
100.0
%
○
F6-06
AI1 input polarity
0: Unipolar (0
~
10V)
1: Bipolar
(
-10
~
10V
)
1
0
×
F6-07
Reserved
F6-08
Reserved
F6-09
AI2 zero offset
-500
~
500
1
0
○
F6-10
AI2 input minimum
rotation speed
0.0%
~
100.0%
0.1%
0.0%
○
F6-11
AI2 10V corresponds to
max. rotation speed
setting
-100.0%
~
100.0%
0.1% 100.0%
○
F6-12
AI2 terminal after
switching corresponds
to max. rotation speed
-100.0%
~
100.0%
0.01% 25.0%
○
F6-13
AI2 input filtering time 0.00S
~
10.00S
0.01S
0.10S
○
F6-14
AI2 input gain
0.01%
~
600.00%
0.01
100.0%
○
F6-15
AI2 input polarity
0: Unipolar
(
0
~
10V
)
1: Bipolar
(
-10
~
10V
)
1
0
×
F6-16
AO1 multi-function
analog quantity output
terminal function
selection
0: Operation rotation
speed
1: setting rotation speed
2: Output current
3: AI1
4: AI2
1
0
○
F6-17
AO2 multi-function
analog quantity output
1
0
○