1.
A disturbance causes the PV to drop, as Dir is positioned upwards, AQ increases until PV corresponds
again to SP.
2.
A disturbance causes the PV to drop, as Dir is positioned upwards, AQ decreases until PV
corresponds again to SP.
Dir is coordinated to the basic conduct of a control loop. The direction (dir) cannot be changed
during the term of the function. The change in Dir here is shown for the purposes of clarification.
3.
As AQ is set to 0 by means of the input R, PV changes. This is based on the fact that PV increases,
which on account of Dir = upwards causes AQ to drop.
Description
Description
Description
Description of
of
of
of Function
Function
Function
Function
If the input A/M is set to 0, then the special function issues output AQ with the value that you
set with parameter Mq.
If the input A/M is set to 1, then automatic mode commences. As an integral sum the value Mq
is adopted, the controller function begins the calculations in accordance with the formulas given
in Control and regulate basics. The updated value PV is used to calculate in the formulas.
Updated value PV = (PV * gain) + offset
If the updated value PV = SP, then the special function does not change the value of AQ.
Dir = u (timing diagram numbers 1 and 3)
•
If the updated value PV > SP, then the special function reduces the value of AQ.
•
If the updated value PV < SP, then the special function increases the value of AQ.
Dir = downwards/- (timing diagram number 2)
Содержание xLogic
Страница 1: ......
Страница 2: ......
Страница 102: ...100 100 100 100 B B B B Blocks Blocks Blocks Blocks...
Страница 105: ...103 103 103 103 G G G G M M M M status status status status...
Страница 106: ...104 104 104 104 H H H H AM AM AM AM value value value value...
Страница 164: ...162 162 162 162 If the Memory Read block had been triggered the Q1 of ELC 12 CPU will be set 1...
Страница 204: ...202 202 202 202 Step Step Step Step 6 6 6 6 Moving Moving Moving Moving...
Страница 226: ...224 224 224 224...