33
Horizontal
Adjust measuring units
Place the Measuring units on the rods, make sure they are at the approximately same
rotational angle and radius. You need to place the measuring units with an offset, see
image. Also make sure that the adjustment knob is adjustable in both directions.
1. Place the Measuring units at 9
o’clock. Adjust the laser line to
the centre of both targets. Use
the adjustment knobs and/or
move the detectors on the rods.
2. Turn the shafts 180º. Make a
mark on the rods or machine
halfway between the laser line
and centre of both targets.
3. Adjust the laser beams half way
to the centre of targets. Use the
adjustment knobs and/or move
the detectors on the rods.
4. Adjust the movable machine un-
til the laser beam hits the centre
of both targets.
5. Turn the shafts 180º. Check if
both laser lines hit the targets. If
not, repeat step 3–5.
Turn shafts to 12 o’clock. Repeat all
steps for vertical adjustment.