The
EASTWOOD ABRASIVE MEDIA BLAST CABINET – B60
is specifically designed with heavy-duty components and a quality powder coated finish to provide
years of trouble-free service. It features an LED work lamp for increased visibility and a baffled, flow-through ventilation design with an external vacuum
connection for portable or bolt-on vacuums.
SAFETY INFORMATION
WARNING indicates a hazardous situation which, if not avoided, will result in death or serious injury.
READ INSTRUCTIONS
Thoroughly read and understand this manual before using the Eastwood Abrasive Media Blast Cabinet – B60. Save for future reference.
ELECTRIC SHOCK HAZARD!
•
Always
plug into a properly grounded outlet.
• Under certain conditions (e.g. atmospheric humidity levels, type of media being used and/or type of media being blasted), the friction
of abrasive blasting may generate static electricity and result in shocking. We recommend grounding the blast cabinet in accordance
with local electrical codes.
• For indoor use only.
HEALTH HAZARD!
• Do not use with sand containing crystalline silica. Exposure to crystalline silica may cause silicosis, a serious lung disease,
cancer, and death.
• Dust generated by the blasting process can contain hazardous materials such as lead, zinc chromate, cadmium, and other toxic
compounds. Always wear a NIOSH-approved breathing apparatus when abrasive blasting.
•
Never
operate the blast cabinet with the door open. Always make sure the door is securely latched and sealed before operating.
•
Never
operate the blast cabinet without a properly filtered shop-type, dust collecting vacuum. If dust is seeping out of your
cabinet, stop immediately and replace vacuum filter!
OPERATION WARNINGS!
•
Never overload the blast cabinet.
Maximum weight capacity of object to be blasted is 132 lbs.
Maximum weight capacity of blast media is
100 lbs.
• Inlet air pressure must not exceed 120 PSI.
Excessive air pressure can cause permanent damage to the unit and personal injury.
• Disconnect air supply before making adjustments, changing accessories, or storing the cabinet.
• Never use bottled gas as an air source for this cabinet.
SPECIFICATIONS
• Electrical current requirement (lamp): 120 Volt AC, 60hz; 0.034 amp
• Air supply requirements: 7 CFM @ 90 PSI.
• Internal Dimensions: 36" wide x 24" deep x 23" high.
36.25"
24.25"
58
.7
5"
Always use a clean, dry, regulated air supply.
Moisture and or oil in air supply will cause
clogging of blast media.