4
Eastwood Technical Assistance: 800.544.5118 >> [email protected]
REquIRED ITEMS
Before you begin using the Eastwood Versa Cut Plasma Cutter make sure you have the following:
• A clean, dry air supply source for the torch. An air compressor capable of delivering 5-7 CFM @ 60 PSI is required.
You can even use a portable air tank with regulator. The air supply must be dry and the use of a moisture trap is
strongly recommended.
• Eastwood recommends at a minimum a properly grounded 110-120 VAC 50/60Hz., 20 Amp circuit or 220-240 VAC
50/60Hz., 30 Amp circuit. NOTE: Unit must be grounded to work properly and safely!
• A clean, safe, well-lit, dry, and well-ventilated work area.
• A non-flammable, long sleeve shirt or jacket.
• Heavy Duty Welding Gloves (Eastwood #12590 or equivalent)
• Auto Darkening Welding Mask (Eastwood #13203 or glasses Eastwood #13948) to provide eye protection during
cutting operations.
POWER REquIREMENTS
The Eastwood Versa-Cut Plasma Cutter is voltage sensing; it will automatically operate on 110-120 VAC, 50/60Hz., or 220-240
VAC, 50/60 Hz. Our Versa-Cut Plasma Cutter is supplied with the popular NEMA 50P plug, requiring a NEMA-50R recepticle. If
a 220-240 VAC, 30 Amp outlet is used a UL listed 30 Amp plug may be installed by a licensed and qualified electrician.
BEFORE YOu BEGIN
Remove all items from the box. Compare with list below to make sure unit is complete.
• Versa-Cut Plasma Cutter
• Torch and 20’ Supply Line.
• 1’ NEMA 50 240 Volt to 120 Volt grounded adapter cord.
• 10’ Ground Lead and clamp.
• Instruction Booklet
• Face Shield
• Extra Electrode and Nozzle