7
Form E-551
7.
After aligning the upper portion of blade link return the two socket head cap screws and secure it using
allen key.
Replacement of Sharpening Wheels
Removing the Sharpening Wheels
1.
Remove the thumb screw found on the font portion of tool head cover which secures the cover to the tool
head.
2.
Carefully swing the tool head cover and move it upwards to ensure it is in upper position.
3.
Ensure that the reciprocating housing is in upper position.
4.
Using allen wrench release the two socket head cap screws from the top of the blade link.
5.
Move the blade link upwards along with the coupler assembly and the knife.
6.
After the blade link, coupler assembly and knife are completely removed from the reciprocating housing,
remove the rotating tool head assembly as per the instructions below.
7.
Disconnect all wires connected to intellicut.
8.
Hold the bottom of the rotating tool head in one hand and then release the screw which holds the rotating
tool head housing to the shaft.
9.
Now rotating tool head drops down.
10.
Using allen key remove the screws which hold the sharpening wheels and remove the worn-out
sharpening wheels