ADJUSTMENTS AND REPLACEMENTS
12
01JUN99 – 5B6331
Caution
To prevent contamination of the developer when you install the DEVELOPER RACK and the FIXER RACK:
• Use the SPLASH GUARD.
• Install the FIXER RACK first.
[7] Place the SPLASH GUARD between the DEVELOPER and FIXER TANKS.
[8] Slowly install the FIXER RACK in the FIXER TANK.
[9] Remove the SPLASH GUARD.
[10] Slowly install the DEVELOPER RACK.
Important
Check that the LOCKING TABS on the EXIT RACK engage the LOCKING TABS on the DRYER RACK.
[11] Install:
• WASH RACK
• DETECTOR CROSSOVER
• FIXER/WASH CROSSOVER
• DEVELOPER/FIXER CROSSOVER
• DRYER RACK
• EXIT RACK
[12] Check that the RACKS and CROSSOVERS are seated correctly.
[13] Install:
• WATER RESERVOIR and WATER DISCONNECT
• EVAPORATION COVERS
• WET SECTION COVER
[14] Close the TOP COVER.
H150_0134BA
EXIT RACK
EXIT RACK
2 LOCKING TABS
2 LOCKING TABS
DRYER
RACK
H150_0134BCA