Plumbing
5B6331 – 01JUN99
43
Removing the DEVELOPER FILTER
Warning
Dangerous Voltage
[1] De-energize the PROCESSOR.
[2] Lift the TOP COVER.
[3] Remove:
• WET SECTION COVER
• REPLENISHMENT HOSE from the
MANDREL ASSEMBLY
[4] Rotate the MANDREL ASSEMBLY until the notch
in the top of the ASSEMBLY aligns with the LEVEL
SENSOR HOUSING CLIP.
Note
When you remove the MANDREL ASSEMBLY, place a
DRIP TRAY under it to prevent contamination of the
fixer.
[5] Remove the MANDREL ASSEMBLY by pulling it
straight up.
[6] Remove:
• WING NUT
• DEVELOPER FILTER
[7] Install a new DEVELOPER FILTER.
[8] Rotate the MANDREL ASSEMBLY until the
LEVEL SENSOR HOUSING CLIP is in the
“LOCKED” position.
[9] Assemble the PROCESSOR.
LOCKED
UNLOCKED
H127_0061BA
H127_0061BCA
HOUSING
MANDREL
HOUSING CLIP
LEVEL SENSOR
H127_0135CA
WING NUT
HOUSING
SENSOR
LEVEL
DEVELOPER
ASSEMBLY
MANDREL
FILTER
H127_0135CCB
REPLENISHMENT
HOSE