Electrical
5B6331 – 01JUN99
85
Adjusting the DETECTOR SWITCH Up and Down
Warning
Dangerous Voltage
[1] Energize the PROCESSOR.
[2] Press the “FILM DETECT” key on the internal
diagnostics menu. See the Diagnostics Manual,
Publication Number 5B6333.
[3] Press the “DRIVE SIDE” key to monitor the drive
side DETECTOR SWITCH.
Note
An audible ALARM will sound whenever film is detected
by the selected DETECTOR SWITCH.
[4] Manually, separate the DETECTOR
CROSSOVER ROLLERS.
[5] With the DETECTOR CROSSOVER ROLLERS
separated, feed a 2.5 cm (1 in.) wide strip of film
between the DETECTOR CROSSOVER
ROLLERS on the drive side of the PROCESSOR.
[6] Loosen the 2 SCREWS that hold the SWITCH
PLATE to the FILM ACCUMULATOR HOUSING
on the drive side of the PROCESSOR.
[7] Move the SWITCH PLATE ASSEMBLY to the “UP”
position.
[8] Slowly, move the SWITCH PLATE down until the
internal diagnostics indicate a “Film Detected”
message for the drive side DETECTOR SWITCH.
[9] Move the SWITCH PLATE down approximately
another 1 - 2 mm (0.04 - 0.08 in.).
[10] Check that the SWITCH PLATE remains in the
vertical position while you tighten the 2 SCREWS
that hold the SWITCH PLATE in position.
[11] Remove the strip of film from between the
DETECTOR CROSSOVER ROLLERS.
[12] Locate the DETECTOR SWITCH on the non-drive
side of the PROCESSOR.
[13] Do Steps 3 - 10 for the SWITCH PLATE on the
non-drive side of the PROCESSOR.
H127_0155CC
H127_0155CCB
DRIVE SIDE
NON-DRIVE SIDE
ROLLER
DETECTOR
CROSSOVER
strip of film