5. Specifications:

Working Pressure:

1800 psi*

Tested Pressure:

3000 psi*

Visual Level Indication:

Magnetic

Primary Materials:

316 Stainless Steel and Aluminum

Carrying Case:

Optional

Size:

3000 cc

EASTERN ENERGY SERVICES PTE LTD.

60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG 415979 Singapore
Telephone: +65-6748 6911 Fax: +65-6748 6912
Email: [email protected] Website: 

www.eesgroup.com

Содержание DuraSite 3000

Страница 1: ...EASTERN ENERGY SERVICES PTE LTD 60 Kaki Bukit Place 02 19 Eunos Tech Park Singapore SG 415979 Singapore Telephone 65 6748 6911 Fax 65 6748 6912 Email info eesgroup com Website www eesgroup com...

Страница 2: ...Theory of Operation 7 8 DuraSite Installation Use 8 9 Cylinder Maintenance 10 10 Diagrams DuraSite Sample Vessel 12 Adjustable Relief Valve Optional 13 EASTERN ENERGY SERVICES PTE LTD 60 Kaki Bukit Pl...

Страница 3: ...to your question can not be found within this manual please contact YZ Systems at 1 936 788 5593 When calling please have on hand this manual for potential review Also be prepared to provide the follo...

Страница 4: ...of the DuraSite Sample Vessel are illustrated here EASTERN ENERGY SERVICES PTE LTD 60 Kaki Bukit Place 02 19 Eunos Tech Park Singapore SG 415979 Singapore Telephone 65 6748 6911 Fax 65 6748 6912 Emai...

Страница 5: ...n Magnetic Primary Materials 316 Stainless Steel and Aluminum Carrying Case Optional Size 3000 cc EASTERN ENERGY SERVICES PTE LTD 60 Kaki Bukit Place 02 19 Eunos Tech Park Singapore SG 415979 Singapor...

Страница 6: ...te Sample Vessel permits the user to remove a liquid or gas hydrocarbon sample from a pipeline sampling device or other location This is accomplished without changing the pressure of the product or ex...

Страница 7: ...with the magnetic sensor to determine the level of the sample fluid within the vessel A visual level indication can be observed on the DuraSite vessel by the position of the magnetic level marker on...

Страница 8: ...ater than the product supply pressure reading If not repeat Step 1 above Step 3 Once the vessel is connected to the product supply it is necessary to vent a small amount of product prior to filling th...

Страница 9: ...a small amount of product from the vessel removesunmixed product fromthetee relief device gauge etc The unit can now be connected to a chromatograph and the product analyzed Step 10 After analyzing th...

Страница 10: ...s shown on YZ drawings Components may be replaced by the factory or user observing Tie Rod Nut tightening torque values Additionally at least once a year the end caps tie rods and cylinder must be tho...

Страница 11: ...ks or dents 3 Do not install a rupture disc that has been previously installed and removed from the disc holder as reinstalling may adversely affect the joint sealing capabilities and or performance o...

Страница 12: ...uraSite Sample Vessel EASTERN ENERGY SERVICES PTE LTD 60 Kaki Bukit Place 02 19 Eunos Tech Park Singapore SG 415979 Singapore Telephone 65 6748 6911 Fax 65 6748 6912 Email info eesgroup com Website ww...

Страница 13: ...ction S Standard visual indicator 4 1 4 FNPT 8 1 8 FNPT Relieving Pressure Factory set per customer specification Example Model RV18 8 1450 relief valve 800 1800 psig range 1 8 FNPT discharge connecti...

Отзывы: