66
Parameter
llustration
T1
Outlet water temperature of
backup heater
T1B
Outlet water temperature of
additional heating source
T1S
Target outlet water temperature
T2
Temperature of refrigerant at
outlet /inlet of plate heat
exchanger when in heat
mode/cool mode
T2B
Temperature of refrigerant
at let outlet /inlet of plate
heat exchanger when in heat
mode/cool mode
T3
Temperature of tube at
outlet/inlet of condenser
when in cool/heat mode
T4
Ambient temperature
T5
Temperature of domestic
hot water
Th
Suction temperature
Tp
Discharge temperature
TW_in
Inlet water temperature of plate
heat exchanger
TW_out
Outlet water temperature of
plate heat exchanger
AHS
Additional heating source
IBH1
The first backup heater
IBH 2
The second backup heater
TBH
Backup heater in the domestic
hot water tank
Pe
Evaporate/condense pressure
in cool/heat mode
10.7.14 Description of terms
The terms related to this unit are shown in the table
below.
Use ▼, ▲,
▼
,
▲
to scroll and use OK to select YES or
NON to enable or disable the auto restart function. If the
auto restart function is enabled, when power returns after
a power supply failure, the AUTO RESTART function
reapplies the user interface settings at the time of the
power supply failure. If this function is disabled, when
power returns after a power supply failure, the unit won’t
auto restart.
Before switching on the unit, read following
recommendations:
The installer is obliged to verify correct operation of unit
after installation.
11 TEST RUN AND FINAL
CHECKS
11.1 Final checks
How to set the AUTO RESTART
Go to MENU> FOR SERVICEMAN>
AUTO RESTART
12.3 FLOOR DRYING UP
The unit will operate floor
drying on 09:00 16-12-2015.
OK
CONFIRM
About AUTO RESTART
The AUTO RESTART function is used to select whether
the unit reapplies the user interface settings at the time
when power returns after a power supply failure.
10.7.13 AUTO RESTART
During floor drying, all the buttons except OK are invalid.
When the heat pump malfunctions, the floor drying mode
will turn off when the backup heater and additional
heating source is unavailable. If you want to turn off floor
drying up, please press OK. The following page will be
displayed:
Use
▼
▲
to scroll the cursor to YES and press OK. Floor
drying will turn off.
t_DRYUP
t_HIGHPEAK
T1S
t
t_DRYD
T_DRYPEAK
When the cursor is on OPERATE FLOOR DRYING? Use
▼
▲
to scroll to YES and press OK. The page will be
displayed as follows:
12.3 FLOOR DRYING UP
Do you want to turn off the
floor drying up function?
SCROLL
OK
CONFIRM
NO
YES
YES
YES NO
NO
13 AUTO RESTART
SCROLL
COOL/HEAT MODE
DHW MODE
V.1