55
Procedure
To change one or more field settings, proceed as follows.
Use ▼ ▲ to navigate and use ▼ ▲ to adjust the
numerical value. Press OK. The password is 234, if it is
correct, the following page will appear:
Temperature values displayed on the wired controller (user interface) are in °C.
CAUTION
Keys
Function
MENU
• Go to the menu structure(on the home page)
BACK
• Come back to the up level
◄►
▼▲ • Navigate the cursor on the display
• Navigate in the menu structure
• Adjust settings
ON/OFF
• Turn on/off the space heating/cooling operation or DHW
mode
• Turn on/or off functions in the menu structure
UNLOCK
• Long press for unlock /lock the controller
• Unlock /lock some functions such as “DHW temperature
adjusting ”
OK
• Go to the next step when programming a schedule in the
menu structure; and confirm a selection to enter in the
submenu of the menu structure.
About FOR SERVICEMAN
“FOR SERVICEMAN” is designed for the installer to set
the parameter.
How to go to FOR SERVICEMAN
Go to MENU> FOR SERVICEMAN. Press OK
Setting the composition of equipment.
Setting the parameter.
Use ▼ ▲ to scroll and use “ok” to enter submenu for
setting the parameters.
Please input the password:
ADJUST
SCROLL
OK
ENTER
2
3 4
FOR SERVICEMAN
SCROLL
OK
ENTER
FOR SERVICEMAN
1. DHW MODE SETTING
2. COOL MODE SETTING
3. HEAT MODE SETTING
4. AUTO MODE SETTING
5. TEMP.TYPE SETTING
6. ROOM THERMOSTAT
7. OTHER HEATING SOURCE
8. HOLIDAY AWAY MODE SETTING
9. SERVICE CALL SETTING
10. RESTORE FACTORY SETTINGS
11. TEST RUN
12. SPECIAL FUNCTION
13. AUTO RESTART
SCROLL
OK
ENTER
FOR SERVICEMAN
About DHW mode
DHW
:
domestic hot water
DHW MODE SETTING typically consists of the
following:
How to set the DHW mode
To determine whether the DHW mode is effective.
Go to MENU> FOR SERVICEMAN> DHW MODE
SETTING. Press OK. The following page is displayed:
10.7.1 DHW control
DHW MODE: enable or disable the DHW mode
TANK HEATER: set whether the booster heater is
available or not
DISINFECT
:
set the parameters for disinfection
DHW PRIORITY
:
set the priority between domestic
hot water heating and space operation
DHW PUMP: set the parameters for DHW pump
operation. The functions above apply only to
installations with a domestic hot water tank.
Use ▼ ▲ to scroll and OK for enter. When the cursor is
on YES, Press OK to set the DHW MODE as effective.
When the cursor is on NON, press OK to set the DHW
MODE as ineffective.
1 DHW MODE SETTING
YES
YES
YES
YES
YES
NON
NON
NON
NON
NON
SCROLL
OK
ENTER
1.1. DHW MODE
1.2. TANK HEATER
1.3. DISINFECT
1.4. DHW PRIORITY
1.5. DHW PUMP
V.1
Содержание ETH50VMR