4810 Clover Road • Greensboro, NC 27450 • 1-800-336-2776 • www.eagleequip.com • © Eagle Equipment 2017.12 • page 23
12. GRAM-OZ CONVERSION
This operation is for counterweight unit conversion (gram-Oz).
1. Press the STOP key and a+ key or a-, the display will show Figure 12-1 which denotes the current
unit is grams.
2. Press b+ or b- key, the display will show Figure 12-2, which denotes the current unit is ounces.
3. Press b+ or b- key to switch units between grams and ounces.
4. Press a+ key to save setup and exit.
13. INCH AND MM CONVERSION
To change the input dimension from B value and D value conversion (INCH-MM): Press INCH/MM key,
the LED 6 display value B and LED 7 display value D can change between inch and millimeter. If in the
right LED display window has a period ( . ) the current measure is INCH, if not, long measure is MM.
14. PROTECTION HOOD FUNCTION SETTING
This function setting is to start the machine directly after the protection hood has been laid down or to
start the machine by laying down protection hood and pressing START.
When function is on:
- After laying down the protection hood, the wheel rotates, then the machine enters measure state.
When function is off:
- After laying down protection hood, the START key should be pressed for entering measure state.
Operation process is as follows:
1. Press [F] key and STOP key (Figure 24). The right display shows the currently state. “ON” denotes
function is on. “OFF” denotes function is off.
2. Press [b+] or [b-] key to shift protection hood function between “ON” and “OFF”
3. Press [a+] key to save current settings and exit. The setup will remain programmed even after
turning the equipment off.
unt.
=
GR
Figure 12-1
unt.
=
Oz
Figure 12-2
Ast.
=
On
Figure 14-1