4810 Clover Road • Greensboro, NC 27450 • 1-800-336-2776 • www.eagleequip.com • © Eagle Equipment 2017.12 • page 14
7. INPUT METHODS OF RIM DATA AND WHEEL BALANCE OPERATION
7.1 THE POWER-ON STATE OF THE MACHINE
After the machine is powered on, it starts initialization automatically. The initialization will be completed
after two seconds. Then the machine enters normal dynamic (clamp counterweights on the correction
plane of the both edged sides of rim) mode automatically (Figure 5), ready for input data of rim.
7.2 WHEEL INPUT METHOD FOR NORMAL DYNAMIC BALANCE MODE
1. After the machine is powered on, it enters the normal balance mode
2. Input data of rim
Rotate the measure scale. Pull the scale head to the inside concave on the edge of the rim (Figure 7-2),
all LEDs will be off. The screen will display (Figure 7-3) waiting to put back scale.
When the scale is back to zero position, LED display value is data of rim.
3. When measure values with fact value of rim differ, you need self-calibration of scales, then measure
again or manual input rim data.
4. Input data of rim width. Use manual plastic width measure scale, measure the width value of rim
then press b+ or b- key input data manually.
7.3 THE DATA INPUT METHOD OF ALU-S MODE:
From normal mode, you do not need to input rim data again, just press ALU key to change to the
selected mode. The ALU-S mode has a special input method. ALU-S means “special mode”, included
below are two kinds of modes (Figure 7-4):
Figure 7-2
8.0
5.7
14.0
Figure 7-1
---
5.7
---
Figure 7-3
Figure 7-4