Installation, Operation and Parts Manual
EE-MR35
14
Step 7: Trial running.
Get familiar with lift controls before loading vehicle onto the lift.
No abnormal sound or leakage before loading.
Run the lift for 5-6 cycles without load.
The cylinder is self-bleeding. After bleeding system, fluid level in power unit reservoir may be down.
Add more oil if necessary to raise lift to full height. It is only necessary to add oil to raise lift to full height.
(For three phase power supply, if the lift doesn't raise and the motor may turn in the wrong direction, in such event, interchange wires U, V in
the control cabinet).
Note: Refer to Annex 1 for fixed installation.
Step 8: Fix the feet protection fenders.
4.4 Items to be checked after installation.
S/N
Check items
YES
NO
1
Rising speed ≥20mm/s;
√
2
Noise with rated load ≤75dB(A);
√
3
Grounding resistance: not bigger than 4Ω;
√
4
Mechanical locks are robust and synchronized when running with rated load ;
√
5
If the control button works as “hold to run”?
√
6
If limit switches work well?
√
7
If grounding wire is connected?
√
8
If rise and lower smoothly?
√
9
If there is no abnormal noise during running with rated load?
√
10
If there is no oil leakage when running with rated load?
√
11
If there is no air leakage when running with rated load?
√
12
If all bolts, nuts or circlips are well secured?
√
13
If max lifting height is 1000mm?
√
14
If safety advices, name plate and logos are clear?
√