Installation, Operation and Parts Manual
EE-6604BWF
-
14
4.2 Installation attentions
4.2.1 Joints of oil hose and wiring must be firmly connected in order to avoid leakage of oil hose and looseness of electrical wires.
4.2.2 All bolts should be firmly screwed up.
4.2.3 Do not place any vehicle on the lift in the case of trial running.
4.3 General Installation Steps
ONLY TRAINED AND QUALIFIED INSTALLERS CAN PERFORM LIFT INSTALLATION DUTIES.
Step 1: Dismantle the package and place lifting platforms onto initially prepared installation foundation using a forklift and lifting straps.
Raise the platform by using a forklift and 2 lifting straps until the mechanical lock is engaged. Dismantle the bolts that fix the platform and
its wooden package and then hoist the platform onto the expected installation site.
Attention 1: Avoid scratching the painting surface and hoses.
Attention 2: Before hoisting, make sure the hoses and wires are well protected against damage.
Attention 3: It is necessary to hold the platform during the hoisting process. Irrelevant person is not allowed in installation area.
Step 2: Connect hydraulic oil hoses.
Connect the oil hoses fittings to the power unit as per the diagram for oil hose connection.
Annex 3.
Attention: Connect as per the marks on the hoses and do not contaminate the hydraulic components during the connection.
It must be taken adequate care that all fittings are securely tightened.
Severe leaking will occur if the hose fittings are not properly tightened.
Step 3: Connect the pneumatic release system
Connect the pneumatic release system by the diagram of air hose connection in Annex 4.
Attention: Do not contaminate the pneumatic components during the connection.
Push upward the button indicated in the following fig and turn the button until the hand of the pressure meter points to the NUMBER ”6” .
Push the button down thereafter.
It is suggested to add ISO VG32 mechanical oil into the oil tank.
Adjust the oil dipping quantity using the button on top of the oil cup.
Step 4: Connect electrical wires.
Refer to electrical connection diagram before making the connection.
Attention: electrical system connection must be done by qualified electricians.
Содержание EE-6604BWF
Страница 10: ...Installation Operation and Parts Manual EE 6604BWF 10 3 3 Dimensions...
Страница 26: ...Installation Operation and Parts Manual EE 6604BWF 26 Annex 2 Electrical schemes and parts list...
Страница 27: ...Installation Operation and Parts Manual EE 6604BWF 27...
Страница 28: ...Installation Operation and Parts Manual EE 6604BWF 28...