47
-
-
4 6
-
F u n c t i o n C o d e T a b l e
EC6000
F u n c t i o n C o d e T a b l e
EC6000
PF
User-defined parameters
PD
-
48
Preset frequency
duration
0.00s
0D30H
0.00~650.00s
PD
-
49
Swing frequency
amplitude
0.0%
0D31H
0.0~100.0%
PD
-
50
Jump frequency
amplitude
0.0%
0D32H
0.0~50.0%
PD
-
51
Rise time of
swing frequency
5.0s
0D33H
0.00~650.0s
PD
-
52
5.0s
0D34H
0.00~650.0s
Falling time of
swing frequency
Function
Code
Parameter Name
Setting Range
Default
Address
PF
-
00
PF parameter
group function
BIT0:
0: Normal display parameter group
1: Only display PF parameter group
BIT1:
0: PF group function mode
1: PF group programming mode
0F00H
00
PF macro
parameter
selection
0: According to the user programming mode
1-100: Call the application macro defined by
the manufacturer
0F01H
0
PF
-
01
PF
-
03
~
PF-67
Edit definition
by user
0000
~
1EFF
0F03H
~
0F27H
0x0001
PF
-
02
PF parameter
group length
3
~
66
0F02H
18
A0
-
00
Function
Code
Control mode
Parameter Name
1000H
Address
A0
Torque control parameters
0: Speed control
1: Torque control
Setting Range
0
Default
A0
-
01
Torque setting
source selection
1000H
000
BIT0: Main frequency source X selection(The
full range of 1-7 option corresponds to A3-02)
0:Function code A3-02 setting
1:AI1 2:AI2 3:AI3
4:PULSE setting 5:Communication setting
6:MIN(AI1,AI2) 7:MAX(AI1,AI2)
BIT1: Auxiliary frequency source Y selection
(The full range of1-7 option corresponds to
A3-03)
0:Function code P5-11 setting
1:AI1 2:AI2 3:AI3
4:PULSE setting 5:Communication setting
6:MIN(AI1,AI2) 7:MAX(AI1,AI2)
The full range of 1-7 option corresponds to
P5-11
A0
-
01
Torque setting
source selection
1000H
000
BIT 2:Main and frequency source selection
0:X×[A3-03]
1:Y×[A3-04]
2:X×[A3-03] + Y×[A3-04]
3:X×[A3-03] - Y×[A3-04]
4:MAX{X×[A3-03],Y×[A3-04]}
5:MIN{X×[A3-03],Y×[A3-04]}
6:Any non-zero value of the main frequency
source X and auxiliary frequency source Y is
valid,and the main frequency source X takes
precedence.
1002H
1003H
1004H
1005H
A0-02
Torque digital
setting in main
frequency source X
-200
~
200.0%
A0-03
A0-04
A0-05
Torque digital
setting in
auxiliary frequency
source Y
Torque setting in
main frequency
source X Gain
Torque setting
in auxiliary
frequency source
Y Gain
-200
~
200.0%
0
~
5.000
0
~
5.000
100%
100%
1.000
1.000
1006H
A0-06
Torque given
filter time
0.0
~
10.00
0.11
1007H
~
1009H
100AH
100BH
100CH
A0-07
~
A0-09
A0-10
A0-11
A0-12
Forward maximum
frequency in
torque control
Reverse maximum
frequency in
torque control
Acceleration time
in torque control
Reserved
0.0Hz~maximum frequency
0.00
~
100
.
00s
-
50.00Hz
50.00Hz
-
0.00s
0.0Hz~maximum frequency
100DH
A0-13
Deceleration time
in torque control
0.00
~
100
.
00s
0.00s
A1
Constant Pressure Water Supply Parameters
Function
Code
Parameter Name
Setting Range
Default
Address
1100H
A1
-
00
Multiple
pump control
0110
BIT0:
0: Multiple pump control is invalid
1: Frequency transform pump fix, no timing
shift
2: Frequency transform pump fix with timing
shift
3: Frequency transform pump circulating, no
timing shift