AVIIVA® EM1
40
1043D - AVIIVA EM1 –04/11
e2v semiconductors SAS 2011
•
ITCMode
¾
Exposure started upon Line 0 trigger.
¾
Exposure ended upon Line1 trigger
Parameter
Value
AcquisitionMode
Continuous
ExposureMode
TriggerControlled
TriggerSelector
"All values"
TriggerMode
Off
TriggerSelector
ExposureStart
TriggerMode
On
TriggerSource
Line0
TriggerActivation
RisingEdge
TriggerSelector
ExposureEnd
TriggerMode
On
TriggerSource
Line1
TriggerActivation
RisingEdge
•
ITCModeWithFrameTrigger
¾
Exposure started upon Line 0 trigger.
¾
Exposure ended upon Line1 trigger.
¾
The Frame is valid on the high level of the Line 2 trigger
Parameter
Value
AcquisitionMode
Continuous
ExposureMode
TriggerControlled
TriggerSelector
"All values"
TriggerMode
Off
TriggerSelector
FrameActive
TriggerMode
On
TriggerSource
Line2
TriggerActivation
LevelHigh
TriggerSelector
ExposureStart
TriggerMode
On
TriggerSource
Line0
TriggerActivation
RisingEdge
TriggerSelector
ExposureEnd
TriggerMode
On
TriggerSource
Line1
TriggerActivation
RisingEdge
In any preset mode using a trigger: if the trigger source is no more active the AcquisitionAbort
feature is required to switch back to the Continuous Timed mode