AVIIVA® EM1
13
1043D - AVIIVA EM1 –04/11
e2v semiconductors SAS 2011
Status LED Behaviour
After less than 2 seconds of power establishment, the LED first lights up in ORANGE. Then after a
Maximum of 30 seconds, the LED must turn in a following colour :
Colour and state
Meaning
Green
and continuous
OK
Green
and blinking slowly
Waiting for Ext Trig (Trig1 and/or Trig2)
Red
and continuous
Camera out of order : Internal firmware error
Orange
and continuous
Initialisation phase
3.2.1
Power Connector
Camera connector type: Hirose HR10A-7R-6PB (male)
Cable connector type: Hirose HR10A-7P-6S (female)
Signal
Pin
Signal
Pin
PWR 1
GND
4
PWR
2
GND
5
PWR 3
GND
6
Camera side description
Power supply from 12 to 24v
Power 11W max with an typical inrush current
peak of
2,2A
during power up
Typical
values
Current
consumption
Camera 12V
24V
EM1
0.5kx14µm
0.75A 0.37A
EM1
1kx14µm
0.80A 0.40A
EM1
2kx10µm
0,73A 0,39A
EM1
2kx14µm
0,79A 0,42A
EM1
4kx10µm
0,81A 0,43A
In standby mode at 24V
:
¾
Power = around
5W
¾
Current =
0,208A
Power up Time
:
Around 40s
InRush current
0
0,2
0,4
0,6
0,8
1
1,2
1,4
1,6
1,8
2
2,2
-0,003
-0,002
-0,001
0
0,001
0,002
0,003
0,004
0,005
Times (s)
C
u
rre
nt
(
A
)