AVIIVA® EM1
39
1043D - AVIIVA EM1 –04/11
e2v semiconductors SAS 2011
•
ITCMaxMode
¾
Exposure started upon Timer1End.
¾
Exposure ended upon Line0 trigger
•
ITCMaxModeWithFrameTrigger
¾
Exposure started upon Timer1End.
¾
Exposure ended upon Line0 trigger.
¾
The Frame is valid on the high level of the Line 2 trigger
Parameter
Value
AcquisitionMode
Continuous
ExposureMode
TriggerControlled
TriggerSelector
"All values"
TriggerMode
Off
TriggerSelector
FrameActive
TriggerMode
On
TriggerSource
Line2
TriggerActivation
LevelHigh
TriggerSelector
ExposureStart
TriggerMode
On
TriggerSource
Timer1End
TriggerActivation
RisingEdge
TriggerSelector
ExposureEnd
TriggerMode
On
TriggerSource
Line0
TriggerActivation
RisingEdge
TimerSelector
Timer1
TimerTriggerSource
Line0
TimerTriggerActivation
RisingEdge
TimerDelayAbs
0
TimerDurationAbs
1
Parameter Value
AcquisitionMode
Continuous
ExposureMode
TriggerControlled
TriggerSelector
"All values"
TriggerMode
Off
TriggerSelector
ExposureStart
TriggerMode
On
TriggerSource
Timer1End
TriggerActivation
RisingEdge
TriggerSelector
ExposureEnd
TriggerMode
On
TriggerSource
Line0
TriggerActivation
RisingEdge
TimerSelector
Timer1
TimerTriggerSource
Line0
TimerTriggerActivation
RisingEdge
TimerDelayAbs
0
TimerDurationAbs
1
The Timer1 is set to
be equivalent to the
readout time