background image

E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH    

[email protected]          e2s.com      

Page 1  of 1

D221-95-001-IS_Issue_D - 01/12/2023

1000Hz PFEER Toxic Gas

1200/500Hz @ 1Hz DIN /PFEER P.T.A.P.

1000Hz @ 0.5Hz(1s on, 1soff) PFEER Gen. Alarm

1.4KHz-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s NF C 48-265

544Hz(100mS)/440Hz (400mS) NF S 32-001

1500/500Hz - (0.5s on , 0.5s off) x3 + 1s gap AS4428

500-1500Hz Sweeping 2 sec on 1 sec off AS4428

500/1200Hz @ 0.26Hz (3.3son, 0.5s off) Netherlands - 

NEN 2575

1000Hz (1s on, 1s off)x7 + (7s on, 1s off) IMO Code 1a

1000Hz (1s on, 1s off)x7 + (7s on, 1s off) IMO Code 1a

420Hz(0.5s on, 0.5s off)x3 + 1s gap ISO 8201 Temporal 

Pattern

1000Hz(0.5s on, 0.5s off)x3 + 1s gap ISO 8201 Temporal 

Pattern

422/775Hz - (0.85 on, 0.5 off) x3 + 1s gap NFPA - 

Temporal Coded

1000/2000Hz @ 1Hz Singapore

300Hz Continuous

440Hz Continuous

470Hz Continuous

500Hz Continuous IMO code 2 (Low)

554Hz Continuous

660Hz Continuous

800Hz IMO code 2 (High)

1200Hz Continuous

2000Hz Continuous 

2400Hz Continuous

440Hz @0.83Hz (50

cycles/minute) Intermittent

470Hz @0.9Hz - 1.1s Intermittent

470Hz @5Hz - (5

cycles/second) Intermittent

544Hz @ 1.14Hz - 0.875s Intermittent

655Hz @ 0.875Hz Intermittent

660Hz @0.28Hz - 1.8sec

on, 1.8sec off Intermittent

660Hz @3.34Hz - 150mS

on, 150mS off Intermittent

745Hz @ 1Hz Intermittent

800Hz - 0.25sec on, 1 sec off Intermittent 

800Hz @ 2Hz IMO code 3.a

(High) Intermittent

1000Hz @ 1Hz Intermittent

2400Hz @ 1Hz Intermittent

2900Hz @ 5Hz Intermittent

363/518Hz @ 1Hz Alternating

450/500Hz @ 2Hz Alternating

554/440Hz @ 1Hz Alternating

554/440Hz @ 0.625Hz Alternating

561/760Hz @0.83Hz (50

cycles/minute) Alternating

800/1000Hz @ 0.875Hz Alternating

2400/2900Hz @ 2Hz Alternating

500/1200Hz @ 0.3Hz Sweeping

560/1055Hz @ 0.18Hz Sweeping

560/1055Hz @ 3.3Hz Sweeping

660/1200Hz @ 1Hz Sweeping

800/1000Hz @ 1Hz Sweeping

800/1000Hz @ 7Hz Sweeping

800/1000Hz @ 50Hz Sweeping

2400/2900Hz @ 7Hz Sweeping

2400/2900Hz @ 1Hz Sweeping

2400/2900Hz @ 50Hz Sweeping

2500/3000Hz @ 2Hz Sweeping

2500/3000Hz @ 7.7Hz Sweeping

800Hz Motor Siren

1200Hz Motor Siren

2400Hz Motor Siren

Stage 1

Set DIP

SW 1

Tone No.

Tone Description

Tone Visual

Stage 1 & 2

DIP SW 1/2

 Settings

1 2 3 4 5 6

Stage 3

Set DIP

SW 1

(S3)

Stage 4

Set DIP

SW 1

(S2 + S3)

0 0 0 0 0 0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

46

47

48

49

50

52

53

54

55

56

57

58

59

60

61

62

63

42

1 0 0 0 0 0

0 1 0 0 0 0

1 1 0 0 0 0

0 0 1 0 0 0

1 0 1 0 0 0

0 1 1 0 0 0

1 1 1 0 0 0

0 0 0 1 0 0

1 0 0 1 0 0

0 1 0 1 0 0

1 1 0 1 0 0

0 0 1 1 0 0

1 0 1 1 0 0

0 1 1 1 0 0

1 1 1 1 0 0

0 0 0 0 1 0

1 0 0 0 1 0

0 1 0 0 1 0

1 1 0 0 1 0

0 0 1 0 1 0

1 0 1 0 1 0

0 1 1 0 1 0

1 1 1 0 1 0

1 1 0 1 1 0

0 0 1 1 1 0

0 1 1 1 1 0

0 0 0 0 0 1

0 1 0 0 0 1

1 1 0 0 0 1

0 0 1 0 0 1

1 0 1 0 0 1

0 1 1 0 0 1

1 1 1 0 0 1 

0 0 0 1 0 1 

0 1 0 1 0 1

1 0 1 1 0 1

0 1 1 1 0 1

1 1 1 1 0 1

0 0 0 0 1 1

1 0 0 0 1 1

0 1 0 0 1 1

1 1 0 0 1 1

0 0 1 0 1 1

1 0 1 0 1 1

0 1 1 0 1 1

1 1 1 0 1 1

0 0 0 1 1 1

1 0 0 1 1 1

0 1 0 1 1 1

1 1 0 1 1 1

0 0 1 1 1 1

1 0 1 1 1 1

0 1 1 1 1 1

0 0 0 1 1 0

1 0 0 1 1 0

0 1 0 1 1 0

1 1 1 1 1 0

1 0 0 0 0 1

1 0 0 1 0 1

1 0 1 1 1 0

1000Hz

1200Hz

500Hz

1s

1000Hz

1s

1s

1600Hz

1400Hz

1s

0.5s

544Hz

0.1s

0.4s

440Hz

0.5s

1500Hz

500Hz

0.5s

0.5s

0.5s

0.5s

1s

2s

1s

3s

0.5s

1500Hz

500Hz

1200Hz

500Hz

1000Hz

1s

1s

1s

1s

1s

1s

1s

1s

1s

1s

1s

1s

1s

1s

7s

7s

420Hz

0.5s

0.5s

0.5s

0.5s

0.5s

1s

1000Hz

0.5s

0.5s

0.5s

0.5s

0.5s

1s

775Hz

422Hz

0.85

0.5s

0.85

0.5s

0.85

2000Hz

1000Hz

f(Hz)

a(s)

b(s)

(f=440, a=0.6, b=0.6)

(f=470, a=0.55, b=0.55)

(f=470, a=0.1, b=0.1)

(f=470, a=0.43, b=0.44)

(f=655, a=0.57, b=0.57)

(f=660, a=1.8, b=1.8)

(f=660, a=0.15, b=0.15)

(f=745, a=0.5, b=0.5)

(f=800, a=0.25, b=1)

(f=800, a=0.25, b=0.25)

(f=1000, a=0.5, b=0.5)

(f=2400, a=0.5, b=0.5)

(f=2900, a=0.1, b=0.1)

f1(Hz)

a(s)

f(Hz)

f1(Hz)

a(s)

a(s)

f(Hz)

(f=363, f1=518, a=0.1)

(f=450, f1=500, a=0.25)

(f=440, f1=554, a=0.5)

(f=440, f1=554, a=0.8)

(f=561, f1=760, a=0.6)

0 0 1 1 0 1

1 1 0 1 0 1

43

44

45

780/600Hz @ 0.96Hz Alternating

800/1000Hz @ 2Hz Alternating

970/800Hz @ 2Hz Alternating

64

Simulated Bell

1 1 1 1 1 1

f1(Hz)

a(s)

a(s)

f(Hz)

(f=800, f1=1000, a=0.57)

(f=2400, f1=2900, a=0.25)

f1(Hz)

a(s)

a(s)

f(Hz)

(f=800, f1=1000, a=0.25)

f1(Hz)

a(s)

a(s)

f(Hz)

(f=600, f1=780, a=0.52)

f1(Hz)

a(s)

a(s)

f(Hz)

(f=800, f1=970, a=0.25)

(f=500, f1=1200, a=3.34)

(f=560, f1=1055, a=5.47)

(f=560, f1=1055, a=0.3)

f1(Hz)

a(s)

f(Hz)

51

600/1250Hz @ 0.125Hz Sweeping

(f=600, f1=1250, a=8)

f(Hz)

a(s)

(f=800, a=1.6)

(f=1200, a=2)

(f=2400, a=1.7)

1450Hz

0.25s

0.69ms

(f=660, f1=1200, a=1)

(f=800, f1=1000, a=1)

(f=800, f1=1000, a=0.14)

(f=800, f1=1000, a=0.02)

(f=2400, f1=2900, a=0.14)

(f=2400, f1=2900, a=1)

(f=2400, f1=2900, a=0.02)

(f=2500, f1=3000, a=0.5)

(f=2500, f1=3000, a=0.13)

(f=300)

(f=440)

(f=470)

(f=500)

(f=554)

(f=660)

(f=800)

(f=1200)

(f=2000)

(f=2400)

f(Hz)

0.5s

2

3

2

24

19

44

44

24

34

34

1

1

1

3

44

44

44

24

44

24

24

24

24

24

24

24

24

8

8

24

8

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

8

8

24

8

21

24

24

24

24

24

24

24

24

24

3

20

44

44

44

1

1

1

1

35

1

1

8

8

8

35

8

8

8

8

8

8

8

8

8

8

8

8

8

19

19

19

19

19

19

19

19

19

19

12

12

12

12

12

12

12

12

12

12

12

12

12

12

12

12

35

35

35

35

35

35

35

35

35

35

f1(Hz)

a(s)

f(Hz)

0.5s

0.5s

1s

Содержание D2xS2F Series

Страница 1: ...above are for the 440Hz Continuous tone nominal input voltage Nominal current at nominal voltage Table 1 Electrical Ratings 2 Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN W...

Страница 2: ...ition 7 EN IEC 60079 7 2015 A1 2018 IEC 60079 7 2018 Edition 5 1 EN 60079 31 2014 IEC 60079 31 2022 Edition 3 Model No Rating D2xS2FDC024 D2xS2HDC024 Ex ec IIC T3 Gc Ta 55 C to 75 C Ex ec IIC T4 Gc Ta...

Страница 3: ...ys be fitted d Replace the cover of the unit taking care not to damage the threads Tighten fully 6 3 Access to the Enclosure Fig 2 Accessing the enclosure To access the chamber loosen the M4 grub scre...

Страница 4: ...lands or blanking plugs A minimum ingress protection rating of IP54 must be maintained for installations in explosive gas atmospheres and IP6X must be maintained for installations in explosive dust at...

Страница 5: ...e 1 DIP switch setting Following table Table 3 is a summary of DC D252 06 001 AC D252 06 005 wiring options Config Voltage Configuration Description Features Product Option Identifier 1a DC Single Sta...

Страница 6: ...duct option V when ordering Spare part code for field installation SP78 0001 Figure 10 End of Line Resistor placement Optional 12 Way Terminal Module 10 Maintenance Overhaul and Repair Maintenance rep...

Страница 7: ...with suitably rated cable glands or stopping plugs EOL Monitoring DC Only End of Line Devices may be fitted between the ve ve terminals of the PCBA Please ensure that the device legs meet the wire si...

Страница 8: ...4V D2xS2HDC024 A is approved for use as an audible signal appliance for fire alarm use Public Mode UL464 CAN ULC S525 and produces a minimum sound pressure level of P2 US 95 51dB A CA 103 8dB A P3 US...

Страница 9: ...1 0 1 0 0 0 0 1 1 0 0 0 1 1 1 0 0 0 0 0 0 1 0 0 1 0 0 1 0 0 0 1 0 1 0 0 1 1 0 1 0 0 0 0 1 1 0 0 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 0 0 1 0 0 1 0 1 1 0 0 1 0 0 0 1 0 1 0 1 0 1 0...

Страница 10: ...MONITORING RESISTOR CUSTOMER SUPPLIED 24V MAX SYSTEM 3K9 MIN 0 5W MIN OR 1K MIN 2 0W MIN 48V MAX SYSTEM 15K MIN 0 5W MIN OR 3K9 MIN 2 0W MIN RECOMMENDED MINIMUM VALUES R1 Stage 1 ve IN Stage 1 ve OUT...

Страница 11: ...e OUT Stage 1 ve OUT Stage 3 ve Stage 1 ve IN H2 H1 Stage 1 ve Stage 1 ve Stage 2 ve Stage 2 ve OF 2 3 R1 S2 S3 R1 S2 R2 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED RECOMMENDED MINIMUM VALUES...

Страница 12: ...to Stage 2 ve Stage 2 ve Two Three Stage Voltage Free Activation Configuration Config 5 Customer Set H1 H2 to Negative Switching See Below Power ve ve Stage 1 Connect Stage 1 ve to Common ve Stage 2 C...

Страница 13: ...2 A B D252 06 005 R S RAIT B ISARD R N POTTS OF NTS 1 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED 1 Earth Earth Stage 2 Stage 3 Common Live IN Live OUT Neutral IN Neutral OUT Earth Stage 1 Stage 2...

Страница 14: ...urance Notification Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 2813 CSA Group Netherlands B V Utrechtseweg 310 6812...

Страница 15: ...the components contained within it are free from substances of very high concern Other Standards and Regulations EN 60529 1992 A2 2013 Degrees of protection provided by enclosures IP code enclosure r...

Страница 16: ...Assurance Notification Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 0518 Rake Lane Eccleston Chester CH4 9JN UK Quali...

Страница 17: ...e components contained within it are free from substances of very high concern Other Standards and Regulations EN 60529 1992 A2 2013 Degrees of protection provided by enclosures IP code enclosure rate...

Страница 18: ...Page left Intentionally blank...

Страница 19: ...Page left Intentionally blank...

Страница 20: ...Page left Intentionally blank...

Отзывы: