Document No. D211-00-401-IS-SC-UL           Issue A          22-07-2022                         Sheet 1 of 4

 

FIRE INSTRUCTION MANUAL 

D2xB1LD2 LED Beacons 
For use in Hazardous Locations

 

1)  Fire Alarm Ratings 

 

1.1  Public Mode Fire Alarm Ratings 

 
The  D2xB1LD2DC024  is  certified  for  use  a  as  public  mode  visual  alarm  device  in  accordance  with  UL1971  Third  Edition  and 
UL1638 Fifth Edition / CAN/ULC-S526 Fourth Edition. 
 
For use in public-mode fire alarm systems the beacon must be installed without the wire guard or plastic lens cover. 
 
The beacon must be set to one of the certified flash patterns of 1Hz, 1.33Hz or 2Hz (for DIP switch settings see section 10). For light 
output ratings see section 2. 
 
Up to 6-off units can be connected to the same wire run without a separate synchronization module and meet the synchronization 
requirements of UL1971 & UL1638 / CAN/ULC-S526. 
 

1.2 Private Mode Fire Alarm Ratings 

 
All models are approved for use as Visual Appliance for use in Fire Alarm Systems – Private Mode. 
 
For private mode fire alarm use the beacons must only be fitted with clear or red plastic lens covers and must be set to one of the 
certified flash patterns of 1Hz, 1.33Hz or 2Hz (for DIP switch settings see section 10). 
For light output ratings see section 12.

 

 

2)  Light output for Fire alarm use 

 

In  order  to  meet  the  requirements  for  UL  1971,  (D2xB1LD2DC024  when  used  with  1Hz,  1.33Hz  or  2Hz  Flash  rates  and  without 
plastic lens cover and wire guard only), the installation must be carried out to the correct NFPA standards and guidelines. 
 

2.1 

Horizontal Light Output Dispersion for wall mounting – public mode 

 
 

15°

15°

30°

45°

60°

75°

90°

90°

30°

45°

60°

75°

 

 

Fig. 1 – Horizontal dispersion angles for wall mounting 

 

Содержание D2xB1LD2

Страница 1: ...n For use in public mode the beacon must be without the wire guard or plastic lens cover See fire instruction manual D211 00 401 IS SC UL 3 2 ATEX IECEx UKEx Ratings Standards EN IEC 60079 0 2018 IEC6...

Страница 2: ...20 C to 50 C Installation must be carried out in compliance with the Canadian Electric Code 4 Zones Gas Group Category and Temperature Classification When connected to an approved system the D2XB1LD2...

Страница 3: ...st first be fitted to the base using the 2 off M4 X 12mm countersunk screws provided Additional feet are available as spare parts if required The unit can also be pole mounted using the NPT Entry in t...

Страница 4: ...used If fitting 2 off wires to one terminal way the sum of the 2 off wires must be a maximum cross sectional area of 2 5mm Strip wires to 8mm Wires may also be fitted using ferrules Terminal screws ne...

Страница 5: ...g crimp terminal to secure the earth conductor to the earth stud The external earth conductor should be at least 4mm2 in size The external earth crimp ring should be located between the two M5 plain w...

Страница 6: ...new lens cover aligning the fixing holes of the guard lens cover and housing Refit the fixings to hold into place the fixings MUST be fitted in the order shown above 14 Maintenance Overhaul Repair Mai...

Страница 7: ...3Hz 104mA 143mA Flashing 2Hz 103mA 146mA Flashing Double Strike 122 4mA 180mA Flashing Triple Strike 144 8mA 211 2mA D2xB1LD2AC115 115Vac 60Hz 115 120Vac 50 60Hz Steady High Power 83mA 102 4mA Steady...

Страница 8: ...on 10 For light output ratings see section 2 Up to 6 off units can be connected to the same wire run without a separate synchronization module and meet the synchronization requirements of UL1971 UL163...

Страница 9: ...h rate 0 100 38 38 35 87 25 97 5 25 90 34 54 32 28 23 37 30 45 75 28 79 26 90 19 48 50 55 21 11 14 28 14 28 55 45 17 27 11 69 11 69 60 40 15 35 10 39 10 39 65 35 13 43 9 09 9 09 70 35 13 43 9 09 9 09...

Страница 10: ...L 1971 UL1638 CAN ULC S526 at worst case min input voltage 2 4 On axis light output rating private mode Table 3 Vertical Light Output Dispersion for Ceiling Mounting Viewing Angle Of Rating Intensity...

Страница 11: ...7QH www e2s com Tel 44 0 208 743 8880 Document No D211 00 401 IS SC UL Issue A 22 07 2022 Sheet 4 of 4 3 Electrical Ratings 3 1 Surge current for Fire Alarm system use Table 6 Surge Currents Model No...

Страница 12: ...attern Apply power to ve ve Stage 2 Flash Pattern Apply power to ve ve Connect Stage 2 to ve Stage 3 Flash Pattern Apply power to ve ve Connect Stage 3 to ve AC LED D2XB1LD2 UNITS Power Live Neutral R...

Страница 13: ...herlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 3G Ex ec IIC T6 T4 T3 T2 T1 Gc II 3D Ex tc I...

Страница 14: ...e and Place of Issue London 22 08 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Страница 15: ...Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 3G Ex ec IIC T6 T4 T3 T2 T1 Gc II 3D Ex tc IIIC Ex tc IIIC T55 75 80...

Страница 16: ...Place of Issue London 22 08 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the marke...

Отзывы: