European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH

 

www.e2s.com

 

Tel: +44 (0)208 743 8880

 

Document No. D211-00-401-IS

 

Issue 1

 

20-08-22

 

 

Sheet 7 of 7

 

 

 

15) 

Electrical Ratings 

 

15.1 

Operating current Consumption 

 

Table 6 – Electrical Ratings 

Model 

Nom. 

Voltage 

Voltage 

Range 

Flash Rate Setting 

Nom. operating 

current

Max. operating 

current

## 

D2xB1LD2DC024 

(D2xB1LD2-H) 

24Vdc 

Regulated 24 

(16-33Vdc)* 

1Hz (60fpm) 

99.5mA 

273mA 

1.33Hz (80 fpm) 

104mA 

275mA 

2Hz (120fpm) 

103mA 

240mA 

D2xB1LD2DC024 

24Vdc 

18-54Vdc** 

Steady High Power 

242mA 

346mA 

Steady Low Power 

128mA 

184mA 

Flashing 1Hz 

99.5mA 

147mA 

Flashing 1.33Hz 

104mA 

143mA 

Flashing 2Hz 

103mA 

146mA 

Flashing Double Strike 

122.4mA 

180mA 

Flashing Triple Strike 

144.8mA 

211.2mA 

D2xB1LD2AC115 

115Vac

 

60Hz

 

115-120Vac 

50/60Hz 

Steady High Power 

83mA 

102.4mA 

Steady Low Power 

53mA 

88.1mA 

Flashing 1Hz 

68mA 

99.7mA 

Flashing 1.33Hz 

64.1mA 

97.6mA 

Flashing 2Hz 

59.2mA 

93.8mA 

Flashing Double Strike 

68.3mA 

99.9mA 

Flashing Triple Strike 

72.8mA 

102.3mA 

D2xB1LD2AC230 

230Vac 

50Hz 

220-230Vac 

50/60Hz 

Steady High Power 

52mA 

52mA 

Steady Low Power 

42mA 

42mA 

Flashing 1Hz 

70mA 

75mA 

Flashing 1.33Hz 

61mA 

75mA 

Flashing 2Hz 

51mA 

62mA 

Flashing Double Strike 

71mA 

71mA 

Flashing Triple Strike 

66mA 

69mA 

* For Public Mode Fire Alarm use 
** For private mode Fire Alarm or General Signalling use 
# nominal rms current at nominal voltage 
## max. rms current at worst-case voltage in voltage range.  

Содержание D2xB1LD2

Страница 1: ...n For use in public mode the beacon must be without the wire guard or plastic lens cover See fire instruction manual D211 00 401 IS SC UL 3 2 ATEX IECEx UKEx Ratings Standards EN IEC 60079 0 2018 IEC6...

Страница 2: ...20 C to 50 C Installation must be carried out in compliance with the Canadian Electric Code 4 Zones Gas Group Category and Temperature Classification When connected to an approved system the D2XB1LD2...

Страница 3: ...st first be fitted to the base using the 2 off M4 X 12mm countersunk screws provided Additional feet are available as spare parts if required The unit can also be pole mounted using the NPT Entry in t...

Страница 4: ...used If fitting 2 off wires to one terminal way the sum of the 2 off wires must be a maximum cross sectional area of 2 5mm Strip wires to 8mm Wires may also be fitted using ferrules Terminal screws ne...

Страница 5: ...g crimp terminal to secure the earth conductor to the earth stud The external earth conductor should be at least 4mm2 in size The external earth crimp ring should be located between the two M5 plain w...

Страница 6: ...new lens cover aligning the fixing holes of the guard lens cover and housing Refit the fixings to hold into place the fixings MUST be fitted in the order shown above 14 Maintenance Overhaul Repair Mai...

Страница 7: ...3Hz 104mA 143mA Flashing 2Hz 103mA 146mA Flashing Double Strike 122 4mA 180mA Flashing Triple Strike 144 8mA 211 2mA D2xB1LD2AC115 115Vac 60Hz 115 120Vac 50 60Hz Steady High Power 83mA 102 4mA Steady...

Страница 8: ...on 10 For light output ratings see section 2 Up to 6 off units can be connected to the same wire run without a separate synchronization module and meet the synchronization requirements of UL1971 UL163...

Страница 9: ...h rate 0 100 38 38 35 87 25 97 5 25 90 34 54 32 28 23 37 30 45 75 28 79 26 90 19 48 50 55 21 11 14 28 14 28 55 45 17 27 11 69 11 69 60 40 15 35 10 39 10 39 65 35 13 43 9 09 9 09 70 35 13 43 9 09 9 09...

Страница 10: ...L 1971 UL1638 CAN ULC S526 at worst case min input voltage 2 4 On axis light output rating private mode Table 3 Vertical Light Output Dispersion for Ceiling Mounting Viewing Angle Of Rating Intensity...

Страница 11: ...7QH www e2s com Tel 44 0 208 743 8880 Document No D211 00 401 IS SC UL Issue A 22 07 2022 Sheet 4 of 4 3 Electrical Ratings 3 1 Surge current for Fire Alarm system use Table 6 Surge Currents Model No...

Страница 12: ...attern Apply power to ve ve Stage 2 Flash Pattern Apply power to ve ve Connect Stage 2 to ve Stage 3 Flash Pattern Apply power to ve ve Connect Stage 3 to ve AC LED D2XB1LD2 UNITS Power Live Neutral R...

Страница 13: ...herlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 3G Ex ec IIC T6 T4 T3 T2 T1 Gc II 3D Ex tc I...

Страница 14: ...e and Place of Issue London 22 08 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Страница 15: ...Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 3G Ex ec IIC T6 T4 T3 T2 T1 Gc II 3D Ex tc IIIC Ex tc IIIC T55 75 80...

Страница 16: ...Place of Issue London 22 08 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the marke...

Отзывы: