Fig. 8 Dip Switch 
1=ON; 0=OFF 
Example shown: 
100000 = Flashing 1Hz 
(Default setting) 

9.2 

Line Monitoring 

 

On the D2xB1X unit, DC reverse line monitoring can be used 
if required. 
All  DC  beacons  have  a  blocking  diode  fitted  in  their  supply 
input  lines.  An  end  of  line  monitoring  resistor  can  be 
connected across the +ve and 

–ve terminals in the explosion 

proof enclosure. If an end of line resistor is used it must have 
the following values: 
Minimum resistance 3K3 Ohms 

Minimum Power 0.5W 

Minimum resistance 500 Ohms 

Minimum Power 2.0W 

 
The resistor must be connected directly across the +ve and  
-ve  terminals  as  shown  in  the  following  drawing.  Form  the 
resistor  legs  as  shown  in  Fig.  7a,  fit  the  resistor  across  the 
two terminals, as shown in Fig. 7b. 
 

 

 

Fig. 7a End of Line Resistor Forming 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

Fig. 7b End of Line Resistor Placement 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

10) Settings 

 

10.1  Flash Rate Setting 

 

 

 

The  D1xB2LD2  beacon  can  produce  different  flash  patterns 
as  shown  in  Table  1.  The  flash  patterns  are  selected  by 
operation of the flash setting DIP switch on the PCB, Fig 8. 

 
Switch 

 

 

Setting 

S1 Mode 

 

S2 Mode 

    

S3 Mode 

(123456) 

 

 

 

 

 

 

000000 

Steady High Power 

Flashing 1Hz  

Flashing Triple Strike 

000001 

Steady Low Power 

Flashing 1Hz  

Flashing Triple Strike 

100000 

Flashing 1Hz  

Flashing Double Strike  

Flashing Triple Strike 

101000 

Flashing 1.5Hz 

Flashing 2Hz  

Flashing Double Strike 

010000 

Flashing 2Hz  

Flashing Triple Strike 

Flashing Triple Strike 

110000 

Flashing Double Strike 

Steady High Power 

Flashing Triple Strike 

001000 

Flashing Triple Strike 

Flashing 2Hz  

Flashing Double Strike 

 
 
 
 
 
 
 

 
 
 
 
 

Fig. 8 DIP Switch location

 

11) Earthing 

 

The  unit  has  an  external  and  an  internal  earth  terminal, 
(please see fig 9). 
 
Internal earthing  connections should be made  to  the  internal 
Earth terminal in the base of the housing using a ring crimped 
terminal to secure the earth conductor under the earth clamp. 
The  earth  conductor  should  be  at  least  equal  in  size  and 
rating to the incoming power conductors. 
 
External  earthing  connections  should  be  made  to  the  M5 
earth  stud,  using  a  ring  crimp  terminal  to  secure  the  earth 
conductor  to  the  earth  stud.  The  external  earth  conductor 
should be at least 4mm

” 

in size. 

  

 

 
 
 
 
 
 
 

Fig. 9: Internal & External Earth Locations 
 
 
 

End of Line 
Resistor 

Warning 

– high-intensity light source. Avoid 

looking directly at the light source for 
extended periods of time. 

External Earth 
Stud 

Internal Earth 
Terminal 