12) Maintenance, Overhaul & Repair 

 

Maintenance,  repair  and  overhaul  of  the  equipment  should 
only  be  carried  out  by  suitably  qualified  personnel  in 
accordance with the current relevant standards: 

 

EN60079-19 / IEC60079-19 Explosive atmospheres - 
Equipment repair, overhaul and reclamation 
EN 60079-17 / IEC60079-17 Explosive atmospheres - 
Electrical installations inspection and maintenance 

 

To  avoid  a  possible  ELECTROSTACTIC  CHARGE  the  unit 
must only be cleaned with a damp cloth. 

 

Units  must  not  be  opened  while  an  explosive  atmosphere  is 
present. 

 

If  opening  the  unit  during  maintenance  operations  a  clean 
environment must be maintained and any dust layer removed  
 
Flameproof joints are not intended to be repaired. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

13) Interchangeable & Spare Parts 

 

 

 
The  Beacon  lens  cover  is  interchangeable,  contact  E2S  Ltd  for  a 
replacement lens cover available in various colours. 
 
To change the lens cover, unscrew the 4-off M5 socket head screws, 
spring  and  flat  washers  using  a  4mm  Hex  key.  Remove  the  wire 
guard and replace the old lens cover with the new lens cover. 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

Fig. 10 Replacement of beacon lens cover 

 
Fit  the  wire  guard  back  onto  the  housing,  over  the  new  lens  cover 
aligning  the  fixing  holes  of  the  guard,  lens  cover  and  housing.  Refit 
the fixings to hold into place, the fixings MUST be fitted in the order 
shown above. 

 
 

 
 
 

 
 
 
 
 
 

 

 
 
 
 
 
 

 
 
 

Warning 

 

Hot surfaces. External surfaces 

and internal components may be hot after 
operation, take care when handling the 
equipment. 

M5 screw 
M5 spring washer 
M5 flat washer 