11. AC Wiring
A 4-way terminal block is provided on the AC chamber beacon
for power. There are 2-off Live and 2-off Neutral terminals in
total. A 4-way terminal block is provided on the AC cover
beacon for power. There are 2-off Live and 2-off Neutral
terminals in total.
Fig. 5 AC Terminals
12. DC Wiring
A 4-way terminal block is provided on the DC chamber beacon
for power. There are 2-off +ve and 2-off -ve terminals in total.
A 4-way terminal block is provided on the AC cover beacon for
power. There are 2-off +ve and 2-off -ve terminals in total.
Fig. 6 DC Terminals
12.1
Line Monitoring
On BExCBGL2-L2D DC units, dc reverse line monitoring can
be used if required. All DC sounders have a blocking diode
fitted in their supply input lines. An end of line monitoring diode
or an end of line monitoring resistor can be connected across
the +ve and –ve terminals. If an end of line resistor is used it
must have a minimum resistance value of 3k3Ω and a
minimum power rating of 0.5 watts or a minimum resistance
value of 500Ω and a minimum power rating of 2 watts.
The resistor must be connected directly across the +ve and -
ve terminals as shown in the following drawing. The resistor
leads should be kept as short as possible.
Fig. 7 End of Line Resistor Placement
13. Flash Rate Settings
The BExB2L2D beacons can produce different flash patterns
as shown in Table 1. The flash patterns are selected by
operation of the flash setting DIP switch on the PCB, Fig 9.
Fig. 8: DIP Switch Location
Table 1: Switch Positions for Flash Patterns
Switch
Setting
S1 Mode
S2 Mode
S3 Mode
(123456)
(DC & AC)
(DC Only)
(DC Only)
000000
Steady High
Power
Flashing 1Hz
Flashing Triple
Strike
000001
Steady Low
Power
Flashing 1Hz
Flashing Triple
Strike
100000
Flashing 1Hz
Flashing
Double Strike
Flashing Triple
Strike
101000
Flashing
1.5Hz
Flashing 2Hz
Flashing
Double Strike
010000
Flashing 2Hz
Flashing Triple
Strike
Flashing Triple
Strike
110000
Flashing
Double Strike
Steady High
Power
Flashing Triple
Strike
001000
Flashing
Triple Strike
Flashing 2Hz
Flashing
Double Strike
Warning – high-intensity light source. Avoid
looking directly at the light source for
extended periods of time.
End of Line
Resistor
L
L
N
N
E
E
+
+
-
-
S2
S3