ELBCam
1
- Technical Documentation
10.04.2007 © E.L.B. Ex-Geräte Bachmann GmbH & Co. KG Page 4
Editing:
•
Connect the camera with a USB port of your PC, if necessary with the
extension lead enclosed with the camera. The camera is now powered by the
PC and appears like an additional hard disk drive.
•
Operation starts with the same signals as powering-on with the button, but the
blue lamp is on continuously. During data transfer the red lamp is also on.
•
The photos can be found in the folder [character for the drive] \ DCIM \
100Media \ ...
•
Please close all folders, before you unplug the camera.
Battery:
•
Replacing of batteries and removing of the battery cover is prohibited in
hazardous areas.
•
Use of rechargeable batteries prohibited even in Non-ex areas.
•
2 alkaline cells size AAA
•
Battery life during standby about 60 days. Please remove the battery, if you
are not going to use the camera for a long time.
Technical Data
4 Operating Data
Certificate no.:
IBExU 06 ATEX 1021
Kind of protection:
II 2 G Ex ia IIC T4
Ambient temperature:
-20°C ... +50°C
Supply:
2 alkaline cells size AAA
Type of cells:
Duracell MN 2400 AAA, capacity: 1150 mAh ...
... or further cells approved according to EN50020, §10.9:
Manufacturer: Type:
Manufacturer: Type:
Daimon Alkaline
Eveready
Alkaline Energizer No. E92
Duracell Alkaline
Plus
GP
Super Alkaline Battery 24 A
Duracell Alkaline
Procell
Varta Alkaline
No.
4803
Duracell Alkaline
Ultra
Toshiba Alkaline
LR03GR
Energizer Ucar
Gold
Current consumption during operating:
~ 130 mA
during standby:
~ 1 mA