Case:
IP protection:
IP20
Material: ABS
Dimensions:
130 x 32 x 22 mm
Weight:
ca. 50 g (without battery and bag)
Cleaning:
Clean with a soft dry cloth or brush. There are gaps and holes in the case, so do not use a
fluid cleansing agent. Do not clean in hazardous areas because of potential static charging of
the cleaning tool.
5 Safety Advices
In hazardous areas the battery and the USB cover must always be protected against
opening by the locking bag.
Do not open the battery or USB cover in hazardous areas.
In hazardous areas any access to the battery or the USB plug is prohibited.
Operation with rechargeable batteries prohibited, even in the Non-Ex-Area.
After exchanging of the battery, the camera function must be verified before entering
the hazardous area, e. g. by checking the flashing of the lamps after switching on.
USB lead and other accessories (except neck loop and carrier bag) are prohibited to
be taken into hazardous areas.
Read the manual completely and carefully before operation. Only the latest
documentation is valid.
Installation, maintenance and cleaning of the units must only be performed by
persons trained and authorized for this purpose, insofar as they are familiar with the
units.
If it can be assumed that safe operation is no longer possible, switch off the unit and
secure it against being used again.
It is prohibited for the operator or his staff to open the units in a way that is not
described in this manual. This may only be done by specifically authorized personnel
of E.L.B. Ex-Geräte GmbH & Co. KG.
Modifications and conversions to the units are not permissible and will cause the Ex
protection and the guarantee to become void.
E.L.B. Ex-Geräte GmbH & Co. KG is not liable for any consequential damage.
The technical data specified for hazardous areas comply with the values certified in
the European EEx approval. The user bears the sole responsibility of examining the
equipment with regard to its suitability for the intended application and environmental
conditions. E.L.B. Ex-Geräte GmbH & Co. KG accepts no liability for any lack of
suitability.
For the installation, maintenance and cleaning of the units, it is absolutely necessary
to observe the applicable ordinances and provisions concerned with explosion
protection (VDE 0160, VDE 0165 or EN 60079-14, EN 50014 - 50039) as well as the
Accident Prevention Regulations (UVV) and codes of practice in your region.