background image

4

Operating manual EE23 humidity / temperature sensor

1  General

This operation manual is part of the scope of supply and serves for ensuring proper handling and opti-

mal functioning of the device. 

The operation manual shall be read before commissioning the equipment and it shall be provided to all 

staff involved in transport, installation, operation, maintenance and repair.

The operation manual may not be used for the purposes of competition without the written consent of 

E+E Elektronik® and may not be forwarded to third parties. Copies may be made for internal purposes. 

All information, technical data and diagrams included in these instructions are based on the information 

available at the time of writing.

1.1  Explanation of Symbols

This symbol indicates safety information.

It is essential that all safety information is strictly observed. Failure to comply with this information can 

lead to personal injuries or damage to property. E+E Elektronik® assumes no liability if this happens.

This symbol indicates instructions.

The instructions shall be observed in order to reach optimal performance of the device.

1.2  Safety Instructions

1.2.1  General Safety Instructions

•  Avoid any unnecessary mechanical stress and inappropriate use.

• 

Replace the filter cap with utmost care, so that the filter cap does not touch the sensing elements of 

the sensing head at any time.

•  Do never touch the sensing elements.

• 

For sensor cleaning and filter cap replacement please see “Cleaning instructions” at www.epluse.com.

• 

Installation, electrical connection, maintenance and commissioning shall be performed by qualified 

personnel only.

1.2.2  Safety Instructions for the Alarm Output Module with Voltage >50V 

 

(not available for model T5 with remote probe up to 180 °C (356 °F))

•  The alarm output module must be separated from the screw terminals

by the partition plate (see picture). 

•  The enclosure must be properly closed before power on.

•  Power off the device before opening the enclosure. 

1.2.3  Safety Instructions for the Integrated Power Supply (Option AM3)

•  The back cover and the middle (active) part of the EE23 with 

metal enclosure must be grounded during operation. 

•  The E23 enclosure must be properly closed before power on.

•  Power off the device before opening the enclosure. 

Содержание EE23 series

Страница 1: ...BA_EE23_B2_e v1 0 technical data are subject to change 194768 Operation Manual EE23 Humidity Temperature Sensor...

Страница 2: ...equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmf...

Страница 3: ...4 Intallation 10 4 1 Mounting the Enclosure 10 4 2 Mounting the Sensing Probe 11 4 3 Electrical Connection 12 4 4 Connection Versions 12 5 Calibration Adjustment 14 5 1 Definitions 14 5 2 Adjustment...

Страница 4: ...ons The instructions shall be observed in order to reach optimal performance of the device 1 2 Safety Instructions 1 2 1 General Safety Instructions Avoid any unnecessary mechanical stress and inappro...

Страница 5: ...mponents of the device must be separated according to local recycling regulations The electronics shall be disposed of correctly as electronics waste 2 Scope of Supply Included in all versions Accordi...

Страница 6: ...the optional display 3 Status LEDs D1 red continuously on during the calibration routine one short flash confirms reset to factory calibration D2 green flashes during normal operation continuously on...

Страница 7: ...es that the device in calibration adjustment mode 2 indicates measured value above the alarm threshold with alarm module only visual feedback when depressing the S1 push button Fig 1 indicates measure...

Страница 8: ...e optional display 2 Status LEDs Green LED flashing Supply voltage applied Microprocessor is active Red LED constantly lit Error category 1 non critical error can be solved by the user flashing Error...

Страница 9: ...cription Error code display Error category Recommended action Short circuit on voltage output 11 ERROR 01 1 Check wiring of outputs Short circuit on voltage output 21 Short circuit on both voltage out...

Страница 10: ...s pointing downwards or horizontal 3 Wire the terminals inside the back cover according to Fig 10 Connection diagram on Page 12 4 Insert the middle active part into the back cover By this the connecti...

Страница 11: ...mportance for accurate mea surement to avoid T gradients along the probe In case of large T difference between the two sides of the wall it is highly recommended to insert the probe completely up to t...

Страница 12: ...e 13 0 51 85 3 3 34 1 3 horizontal hanging onto the probe cable stainless steel mounting flange drip water loop drip water protection Fig 9 Mounting the sensing probe 4 3 Electrical Connection Power s...

Страница 13: ...2 OUT1 1 plug for 100 240 V metal enclosure front view Description Pins grounding PE 1 phase L1 2 neutral wire N 3 plug for 100 240 V polycarbonate enclosure front view Description Pins phase L1 1 neu...

Страница 14: ...54 F The 1 point adjustment should be used only when the RH and or T range of interest is rather narrow The RH resp T adjustment point should be ideally in the middle of the range of interest Example...

Страница 15: ...the jumper to CAL T 2 Allow for the probe to stabilize at the desired RH T for min 30 minutes 3 For adjustment point 50 RH in the upper half of the T output scale press BUTTON S1 for min 3 seconds to...

Страница 16: ...eeded with an E E original one A polluted filter cap causes longer response time of the device For cleaning of the sensing head please see Cleaning Instructions at www epluse com ee23 7 Troubleshootin...

Страница 17: ...T6 D03M EE23 for T5 D05M EE23T5 Display housing cover in polycarbonate for T1 T2 T4 and T6 D03P EE23 for T5 D05P EE23T5 Mounting flange for probe diameter 12 mm HA010201 Mounting flange 5mm for model...

Страница 18: ...tage for 0 1 V 0 5 V outputs 10 5 35V DC or 12 28V AC for 0 10 V 0 20 mA 4 20 mA outputs 15 0 35V DC or 15 28V AC 100 240V AC 50 60Hz supply module optional Current consumption for voltage output for...

Страница 19: ...ing Range Humidity Sensor Relative humidity RH Temperature degC The gray area shows the allowed measurement range for the humidity sensor Operation beyond this range does not destroy the sensing eleme...

Страница 20: ...0 6460 Office Stuttgart Tel 49 151 538 37 500 E E Elektronik Italy info epluse it Tel 39 02 2707 86 36 E E Elektronik France info epluse fr Tel 33 4 74 72 35 82 E E Elektronik USA office epluse com Of...

Отзывы: