Exposure control
The exposure control for See3CAM_CU51 is provided in the extension menu. The
required exposure value can be entered into the text box and this exposure value will be
applied during exposed image capture.
See3CAM_CU51 supports exposure levels ranging from 1 milli second to 30 seconds.
This can be input through the exposure text box, i.e. for 1 milli second the value of 1
should be entered in the text box, for 1 second the value of 1000 should be set, as 1 second
= 1000 milli seconds. Similarly for 30 seconds the value of 30000 should be set, as 30
seconds = 30000 milli seconds.