e-breathe
• [email protected] • www.e-breathe.de
23
Rev. 5.0
Maintenance and cleaning work may only be carried out by appropriately qualified personnel who are well trained
and familiar with the nature of the task.
3.3 Technical Specification
4. Cleaning and Maintenance
4.1 Cleaning and Disinfection
The following cleaning material is recommended for the daily care of the equipment: PM Desk or Curacid PSA Ultra.
Dilute the cleaning material with lukewarm water and wipe the equipment with a cloth. Use a soft brush on badly
polluted items. Then rinse thoroughly with tap water. Then wipe the individual items with a dry cloth and stand them
to dry.
For immersion disinfection pour cold water into a bowl and add the appropriate quantity PM Desk or Curacid PSA
Ultra. Submerse the Multimask completely and move it around in the water to remove air pockets. After 15 minutes
remove the Multimask from the bowl and rinse under clean water, then allow to dry.
Only the Neoprene face seal can be washed in a washing machine, at maximum 40 degrees and maximum spin speed
of 600 rpm, with regular washing powder.
Important!
Absolutely no solvents, for example, acetone, turpentine or bleach (borax), hot water, high-pressure air or
high-pressure water may be used for cleaning the Multimask.
For more information and instructions on cleaning and preparation of the Multimask Pro, please contact e-breathe
Safety.
Approvals:
CE certified according to EN 12941 / EN 14594 / EN 166
Respiratory protection:
TH2 / TH3 | 3B
Eye protection:
EN 166 Class B
Air flow:
> 160 l/min
Hose connection:
Vario & MM
Temperature range of use:
-10°C up to +40°C <70% RH
Weight head piece:
350g
Material mask body:
PCABS
Material face seal:
foam / silicone / neoprene
Material visor:
PC / CA