4.2.6.1 Ensure that the breathing hose has no cracks or holes and is completely intact. Also check the seals at the hose 

connections. If the hose is not completely intact, do not use it.

4.2.6.2 Screw the round thread connection of the breathing air hose clockwise onto the yellow union nut of the blo-

wer. Make sure that the hose does not twist. See Figure 1.

4.2.6.3 Ensure that the breathing hose is securely and firmly connected to the blower to prevent the ingress of am-

bient air.

4.2.6.4 To remove the breathing hose, unscrew the round thread connection anti-clockwise from the yellow union nut. 

4.2.6 Breathing Hose Assembly / Replacement 

Read the instructions for use enclosed with the head piece carefully.

4.3 Check Before Use 

The following tasks should be performed before using the PAPR.

1. Selection of the system components according to the activity and the required protection class.

- Filter, breathing hose, breathing connection and blower unit.

 

2. Performance of a careful visual inspection of all components and, if necessary, replacement of damaged parts

- Check the breathing hose for cracks and intactness. Also check the seals on the connections.

- Check the gaskets /sealing edge of the filter. Check the condition and intactness of the filter medium. 

- Check the intactness of the seal at the filter box at the thread inlet. 

- Check the filter sealing surface of the mounting on the blower unit for damage.

- Check the blower unit and the battery to make sure they are intact and not damaged.

  

Also refer to the enclosed instructions for use of the filters and the breathing connection.

3. Service Date/Maintenance 

- Switch on the blower and check the entered date of the last service/maintenance in the system information menu.

 

4 Checking the Battery Status 

- Mount the battery into the blower and turn it on. You can read the battery capacity on the display. It is recommended 

to work only with a fully charged battery.

5. Checking the Filter Capacity

- Switch on the blower with the filters to be used and check the filter capacity on the display. 

Note: The Head Piece should be connected to ensure that the measurement value is not falsified. 

- If the available capacity is insufficient, replace the filters.

6 Checking the air flow and the warning devices

A functional test can be performed prior to use with a test tube from e-breathe. Check that the minimum air flow rate 

is still reached and that the warning device is fully functional.

Содержание e-Flow

Страница 1: ...E S O L I D S A F E Willicher Damm 99 41066 M nchengladbach Germany Tel 02161 40 290 0 Fax 02161 40 290 20 www e breathe de info e breathe de Stand Juli 2019 GEBRAUCHSANWEISUNG DEUTSCH S 2 ATEMSCHUTZ...

Страница 2: ...5 7 Warnungen und Alarme 19 4 1 Auspacken Sichtpr fung 9 5 7 1 Warneinrichtungen 19 4 2 Montage Demontage e Flow f r den Gebrauch 9 5 7 2 Warnungen 19 4 2 1 Montage Demontage Gurt Tragesystem 9 5 7 3...

Страница 3: ...difikationen bzw Reparaturen durch Personen die nicht vom Unternehmen erm chtigt sind Sofern Anspr che w hrend der Garantiezeit geltend gemacht werden muss das Kaufdatum belegt werden Von allen M ngel...

Страница 4: ...bl se ausgeschaltet ist oder im Betrieb ausgeht In dieser ungew hnlichen Situation bietet die Aus r stung keinen Schutz zudem besteht die Gefahr der raschen Ansammlung von Kohlendioxid im Kopfteil mit...

Страница 5: ...ften von Gefahrstoffen erfordern spezielle Einsatzregeln Es d rfen nur von e breathe Safety zugelassene Filter verwendet werden Die Verwendung anderer Filter ist nicht zugelas sen und kann den Schutzg...

Страница 6: ...erangaben beachten Folgende Filter sind f r das e breathe e Flow mit PAD Box erh ltlich Filter kombinierbar mit e breathe ecoPAD P3 R PSL Gasfilter Adapter und ecoPAD GF A2 A2B2 ABEK e breathe ecoPAD...

Страница 7: ...eichenden Schutz Deshalb d rfen Ger te ohne entsprechende Warneinrichtungen und Ger te der Klasse TH1P nicht gegen krebserzeugende sehr giftige und radioaktive Stoffe Mikroorganismen Viren Bakterien P...

Страница 8: ...om eingestellten Luftstrom sowie den angeschlossenen Filtern und Kopfteil Temperaturbereich 10 C bis 40 C 70 relative Feuchte Lagertemperatur 0 C bis 30 C 70 relative Feuchte Akkuart Lithium Ionen Lad...

Страница 9: ...dann wieder die Schnalle die Sie zuvor entfernt haben Gurt demontieren Entfernen Sie die Schnalle und ziehen Sie anschlie end den Gurt mit der Seite ohne Schnalle durch die Gurtaufnah men des Gebl ses...

Страница 10: ...die PAD Box Aufnahme Legen Sie anschlie end wie oben beschrieben das ecoPAD P3 in den Gasfilteradapter ein und schrauben Sie den Filterdeckel handfest im Uhrzeigersinn auf den Gasfilteradapter Wichti...

Страница 11: ...n verbrauchten Partikelfilteranteil oder Gasfilteranteil tauschen und die andere Komponente wei terverwenden Sollten Sie den ganzen Filter austauschen wollen halten Sie den Filter an der Seite fest so...

Страница 12: ...nreinigungen und Feuchtigkeit 4 2 5 1 Die korrekte Netzspannung der Stromversorgung muss berpr ft werden Die Batteriespannung des Netzteils muss mit der Netzspannung bereinstimmen 4 2 5 2 Wenn die Spa...

Страница 13: ...r fen Sie auch die Dichtungen an den Anschl ssen Pr fen Sie die Dichtungen den Dichtrand des eingesetzten Filters Pr fen Sie die Unversehrtheit und Intaktheit des Filtermediums Pr fen Sie an der Filte...

Страница 14: ...Sie als Atemanschluss eine Haube Helm Gesichtsschutzschild verwenden kann es bei schweren Arbei ten dazu kommen dass Sie w hrend des Einatmens einen Unterdruck im Atemanschluss erzeugen Es k nnte dann...

Страница 15: ...vor dem n chsten Einsatz des Ger tes beheben m ssen Siehe Abschnitt 5 7 4 5 Ablegen des Gebl ses 4 5 1 Legen Sie das Gebl se nur au erhalb des Gefahrenbereiches bzw des kontaminierten Bereiches ab 4...

Страница 16: ...elf Checks kein Fehler auf wechselt die Anzeige automatisch ins Hauptmen Im Hauptmen werden folgende Informationen angezeigt Eingestellter Volumenstrommodus Ben tigte Filteranzahl Akkukapazit t Restla...

Страница 17: ...nsatzgrenzen kommt und Sie sich auf Stufe 2 oder Stufe 3 befinden regelt das Gebl se automatisch runter auf Stufe 1 Mindestvolumenstrom Diesen Vorgang f hrt das Gebl se aus um die Einsatzzeit zu verl...

Страница 18: ...n folgende Informationen angezeigt Ladezyklen Akkuaufladungen des angeschlossenen Akkus Anzeige der gelaufenen Betriebsstunden des Gebl ses 192 h 11 x 180 l min 5 6 Systeminformationsmen 3 Im Systemin...

Страница 19: ...Akustischer Alarmton Optischer Alarm Quittierbar Ja Restlaufzeit des Akkus ist gering 40 30 min und oder die Akkukapazit t ist 8 Arbeit muss in K rze unter brochen werden und der Akku geladen oder du...

Страница 20: ...Optischer Alarm Vibrationsalarm Quittierbar Ja Err 10 Motorauslastung bzw Drehzahl ist zu hoch der Mindestvolumenstrom kann nicht mehr gehalten werden Err 11 Motor ist blockiert Es kann kein Volumen...

Страница 21: ...u aus Ladeschale ent fernen und vom Hersteller berpr fen lassen rote LED 4x dauerhaftes Blinken Eingangspannung zum La den zu niedrig Netzteil von der Stromquel le trennen und Ladevor gang erneut star...

Страница 22: ...x x x x Akkuwechsel x Filterwechsel x Volumenstrom und Warneinrichtungen pr fen x Austausch der Dichtungen x x Reinigung und Desinfektion x x x Wartung durch e breathe Service durchf hren lassen x Vo...

Страница 23: ...e eindringt und die Kontakte des Akkus nicht mit Fl ssigkeiten in Ber hrung kommen 6 2 3 Reinigung Tragesystem und Gebl seeinheit F r die t gliche Pflege kann handels bliches Sp lmittel verwendet werd...

Страница 24: ...rung berwachungsstelle Institut f r Arbeitsschutz der Deutschen Gesetzlichen Unfallversicherung IFA Alte Heerstra e 111 53757 Sankt Augustin Deutschland Kenn Nr 0121 Nr Beschreibung 1 Produktbezeichnu...

Страница 25: ...n 160 l min 2x e breathe ecoPAD P3 R PSL PM Laborhaube AV TH3 PSL 100 EN 12941 e breathe e Flow Filter System e breathe Partikelfilter P3 R PSL e breathe e Flow PAD System Hauben 160 l min 2x e breath...

Страница 26: ...e e Flow PAD Box als Vollmaskensystem 322005102 3 e breathe e Flow Filter Box als Vollmaskensystem 322005101 4 e Flow PAD Box Aufnahme Box f r ecoPAD Filter 322005001 5 e Flow Filter Box Aufnahme Box...

Страница 27: ...Alarms 44 4 1 Unpacking Visual Inspection 34 5 7 1 Warning Devices 44 4 2 Assembly Disassembly e Flow for Use 34 5 7 2 Warnings 44 4 2 1 Assembly Disassembly Belt and Carrying System 34 5 7 3 Alarms...

Страница 28: ...he producer improper use or modifications or reparations by persons who are not authorised by the company If claims are asserted during the warranty time the date of purchase has to be verified The cu...

Страница 29: ...1 1 Warnings The equipment must not should not be used EN 12941 Blower with Hoods Head Pieces and Suits when the blower is switched off or goes off during operation If the blower turns off by accident...

Страница 30: ...rning characteristics of hazardous substances require special rules of engagement Only filters which are approved by e breathe may be used The use of other filters is not allowed and can lower the pro...

Страница 31: ...rve manufacturer s ins tructions for use The following filters are available for the e breathe e Flow with PAD Box Filter can be combined with e breathe ecoPAD P3 R PSL Gasfilter Adapter und ecoPAD GF...

Страница 32: ...power loss of the blower Consequently it is not allowed to use devices without appropriate warning system and devices of class TH1P against carcinogenic ex tremely toxic and radioactive substances mic...

Страница 33: ...ng on the adjusted air flow and the connected filters and head piece Temperature range 10 C to 40 C 70 relative humidity Storage temperature 0 C to 30 C 70 relative humidity Battery type Lithium Ion C...

Страница 34: ...of the blower Reinstall the buckle you previously removed Belt Disassemble Remove the buckle and pull the belt with the side without the buckle through the blower belt mountings to disas semble the be...

Страница 35: ...gas filter adapter onto the PAD box Then insert the ecoPAD P3 onto the gas filter adapter as described above and screw the filter cover clockwise onto the gas filter adapter hand tight Important The...

Страница 36: ...filter fraction or gas filter fraction and continue to use the other filter component If you want to replace the entire filter hold the filter sideways so that you have the filter holder and filter c...

Страница 37: ...Protect the charger from sunlight direct heat radiation dust dirt and moisture 4 2 5 1 The correct mains voltage of the power supply must be checked The battery voltage of the power supply unit must...

Страница 38: ...hose for cracks and intactness Also check the seals on the connections Check the gaskets sealing edge of the filter Check the condition and intactness of the filter medium Check the intactness of the...

Страница 39: ...stment Air Flow If you use a hood helmet face shield as breathing connection you may generate a negative pressure in the breathing connection during inhalation when performing heavy work This could ca...

Страница 40: ...ote that after leaving the dangerous area you must eliminate the error prior to the next use of the device 4 5 Putting off the Blower 4 5 1 Only remove the blower outside the hazardous area or the con...

Страница 41: ...phase the display automatically switches to the main menu The main menu displays the following information default air flow mode Required number of filters battery capacity remaining battery runtime f...

Страница 42: ...is shown below If the blower reaches its operating limits and is at stage 2 or stage 3 the blower automatically adjusts down to stage 1 minimum air flow This process is performed by the blower to ext...

Страница 43: ...ns are displayed in the operating information menu Charging Cycles Battery Charges of the connected Battery Display of the hours the blower has been in operation 192 h 11 x 180 l min 5 6 System Inform...

Страница 44: ...eration Duration 10 sec once Acoustic alarm Optical alarm Can be switched off Remaining battery runti me is low 40 30 min and or battery capacity is 8 Work must be interrupted shortly and the battery...

Страница 45: ...during operation Acoustic alarm Optical alarm Vibration alarm Can be switched off Err 10 Motor load or mo tor speed is too high the minimum air flow can no longer be achieved Err 11 Motor is blocked N...

Страница 46: ...tation and have it inspected by the manufacturer red LED 4x permanent flashing Input voltage too low to charge Disconnect the power sup ply unit from the power source and restart the char ging process...

Страница 47: ...attery level check x x Battery charging x x x x Battery replacement x Filter replacement x Air flow and warning devices check x Replacement of seals x x Cleaning and disinfection x x x Service and mai...

Страница 48: ...for use Important Make sure that no liquid enters the blower during cleaning and disinfection and no liquid comes into contact with the battery contacts 6 2 3 Cleaning of the carrying system and blow...

Страница 49: ...tzlichen Unfallversicherung IFA Alte Heerstra e 111 53757 Sankt Augustin Germany Kenn Nr 0121 Nr Description 1 Product Description 2 Part No 3 Approved Standards 4 Country of production 5 Manufacturer...

Страница 50: ...Filter System e breathe Particlefilter P3 R PSL e breathe e Flow PAD System Hood 160 l min 2x e breathe ecoPAD P3 R PSL PM Labhood AV TH3 PSL 100 EN 12941 e breathe e Flow Filter System e breathe Par...

Страница 51: ...e Flow PAD Box Full Face Mask System 322005102 3 e breathe e Flow Filter Box Full Face Mask System 322005101 4 e Flow PAD Box Box for ecoPAD Filter 322005001 5 e Flow Filter Box Box for round thread...

Страница 52: ...eable Li Ion Battery 14 4 V 3 4 Ah 49 Wh Must be recycled or disposed of properly Caution charge with dedicated charger only May explode if damaged or dispo sed of in fire Do not short circuit 10 12 1...

Страница 53: ...53 Rev 0 6 info e breathe de www e breathe de e breathe e Flow 13 0 Abbildungen Illustrations 1 2 3 4 5 1 2 3 1 2 4 5 6 7 8 9 10 11 12 Einschalttaste Men knopf Volumenstrom regulieren...

Страница 54: ...54 Rev 0 6 info e breathe de www e breathe de e breathe e Flow Notizen Notes...

Страница 55: ...55 Rev 0 6 info e breathe de www e breathe de e breathe e Flow Notizen Notes...

Страница 56: ...de Online Shop f r Arbeitsschutz www pm atemschutz de service pm atemschutz de Service Partner f r Service im Atemschutz Tel 02161 40 290 0 www pm atemschtuz de info pm atemschutz de www e breathe de...

Отзывы: