15
L I N X W I T H A T R A F L E X I N S T A L L A T I O N
Inner Mounting Plate and Flange Bearing Installation
Version 3
Linx with Atra Flex Installation for Model 424 Automotive Dynamometers
INNER MOUNTING PLATE AND FLANGE BEARING INSTALLATION
Use the following instructions to install the inner mounting plate and flange bearing to
both the stationary and movable dynos.
You will need the following parts:
• 32300001
Flange Bearing with Lock Collar (2)
• 36582471
Bolt, 3/8-16 x 1.5", Flange-Hex (2)
• 36711100
Nut, 9/16-12, Hex (8)
• 36923100
Washer, 3/8", Flat (18)
• 36943101
Washer, 9/16", Flat (8)
• 61300024
Inner Mounting Plate, Stationary Dyno
• 61300027
Inner Mounting Plate, Movable Dyno
• DM150-011-004 Nut, 3/8-16, Hex (2)
• DM150-019-012 Bolt, 3/8-16 x 1", Hex (16)
I
NSTALLING
THE
I
NNER
M
OUNTING
P
LATE
AND
F
LANGE
B
EARING
—M
OVABLE
D
YNO
1
Place the flange bearing on the threaded studs on the inner plate.
2
Loosely secure the flange bearing to the inner plate using four 9/16-inch washers
and four 9/16-inch nuts.
3
Secure the inner mounting plate to the movable dyno using eight 3/8 x 1-inch
bolts and eight 3/8-inch flat washers.
Note:
For above ground installations, use only six 3/8 x 1-inch bolts and
six 3/8-inch flat washers.
4
Verify the flange bearing on the inner mounting plate is centered on the shaft.
Loosen the bearing nuts and center the bearing if necessary.
Figure 7: Secure the Inner Mounting Plate and Flange Bearing to the Movable Dyno
for in ground
installations only
inner mounting plate
flange bearing