Data Recorder  

Stop

 

 

 

Recording

Set Point Select  

Select Local

 

 

 

Setpoint

 

 

 

1A/2A

Auto Manual Control  Automatic

Select   

 

Control mode

PID Control Output  Enable PID

 

 

 

Control outputs

Engage Pre Tune 

No Action

Engage Self Tune 

No Action

Increment Control 

No Action

Output

Decrement Control  No Action

Output

Start Recording

Select Alternate Setpoint

Manual Control Mode

Disable PID Control Outputs

Engages tuning mode selected

Engages tuning mode selected

Increments control output 

percentage (0-100% in 20secs)

Decrements control output 

percentage (100-0% in 20secs)

Outputs

Caution:

 

Plastic pegs prevent fitting of older non-reinforced single relay modules –

Remove the peg to fit dual relays (all dual relay modules have reinforced isolation)

Single Relay

Type & Rating:  

Single pole double throw (SPDT); 2A resistive at 120/240VAC.

Lifetime:  

 

>500,000 operations at rated voltage/current.

Isolation:  

 

Reinforced safety isolation from inputs and other outputs.

Dual Relay

Type & Rating:  

Single pole single throw (SPST),2A resistive at 120/240VAC.

 

 

 

Dual relay modules have shared common.

Lifetime:  

 

>200,000 operations at rated voltage/current.

Isolation:  

 

Reinforced safety isolation from inputs and other outputs.

Linear DC

Ranges  

 

0 to 5, 0 to 10, 1-5, 2 to 10V & 0 to 20, 4 to 20mA (selectable)

 

 

 

with 2% over/under-drive when used for control outputs.

Resolution:    

15 3/4 bit (1 part in 52K)

Accuracy:  

 

0 to 20mA, 4 to 20mA into 500    max, 0 to 10V, 2 to 10V, 0 to 5V into 500    

 

 

 

min updated at about 65ms intervals. (130ms settling time)

Stability: 

 

± 76ppm

Isolation:  

 

Reinforced safety isolation from inputs and other outputs.

Содержание ATC990

Страница 1: ...From lab to production providing a window into the process 1 www dynisco com Rev n a P N n a ECO n a Dynisco ATC990 Graphical 1 4 DIN Process Controller Concise Product Manual Operating Manual...

Страница 2: ...allation safety must be observed e g US National Electrical Code NEC and or Canadian Electrical Code Impairment of protection will occur if the product is used in a manner not specified by the manufac...

Страница 3: ...ntings e Push the boards forward to ensure correct connection to the Display board f Replace the instrument by aligning the boards with the guides in the housing then slowly push the instrument back i...

Страница 4: ...he instrument housing towards rear face of mounting panel until the tongues engage in ratchets and instrument is clamped in position Hold instrument firmly in position apply pressure to bezel only CAU...

Страница 5: ...y marked All connections to the device must be made through a spade format or similar connection with connection to the spade terminal touching both the insulation and conductor material Use a standar...

Страница 6: ...lution Impedance 10M resistive except DC mA 5 and V 47k Temp Stability Error 0 01 of span per C change in ambient temperature Supply Variation Supply voltage influence negligible within supply limits...

Страница 7: ...to 2320 C 32 to 4208 F D 0 to 2315 C 32 to 4199 F E 240 to 1000 C 400 to 1832 F J 200 to 1200 C 328 to 2192 F K 240 to 1373 C 400 to 2503 F L 0 to 762 C 32 to 1402 F N 0 to 1399 C 32 to 2551 F PtRh 20...

Страница 8: ...Scalable from 99999 to 100000 Decimal point selectable from 0 to 3 places but limited to 5 display digits e g 9999 9 Up to 15 scaling values can be defined anywhere between 0 1 and 100 of input Open c...

Страница 9: ...e relay modules Remove the peg to fit dual relays all dual relay modules have reinforced isolation Single Relay Type Rating Single pole double throw SPDT 2A resistive at 120 240VAC Lifetime 500 000 op...

Страница 10: ...8 data bits and 1 stop bit Odd even or no parity Isolation 240V reinforced safety isolation from all inputs and outputs Ethernet Connection Locates in Option Slot A Connection via RJ45 connector on to...

Страница 11: ...cleaning Display Display Type 160 x 80 pixel monochrome graphic LCD with a dual colour red green backlight Display Area 66 54mm W x 37 42mm H Display Characters 0 to 9 a to z A to Z plus and _ Trend...

Страница 12: ...n also be run from the Main Menu It exits to Operation Mode once completed Start Up Errors These messages indicate that a hardware or configuration an error has occurred Caution Do not continue with t...

Страница 13: ...aved time At start of phase Delta reset timeout generator 4 5 saved time Err limit The process reaction goes into the wrong direction after setting the controller output pulse Err Parameter The estima...

Страница 14: ...without DHCP Refer to the User guide from your supplier for help with communications 7 Strain Gauge Calibration Mode Press the to enter calibration mode from any location for quick access see Strain G...

Страница 15: ...tune step is set too high it will create an overshoot and therefore needs to be reduced The pre tune step power is added to manual power and displayed to the user but is not changeable The expected ra...

Страница 16: ...Max actual controller output Standby Active Limit The freezing of the output of the controller will last for a time specified by the Pressure stand by recovery time parameter If the parameter Pressure...

Страница 17: ...ferential Input only applicable if Input2 card fitted and set to non temperature Primary Control Action Reverse or Direct acting Primary Secondary proportional band Integral Time Enter Value of requir...

Страница 18: ...m through which the signal must pass before alarm deactivates Signal change Alarm n Min Minimum time the rate of PV change must be above the alarm threshold for a Rate Of Change Alarm to change state...

Страница 19: ...e day of week used by the internal clock Recorder versions only Set Time w Sets the internal clock Time In hh mm ss Hours Minutes Seconds format Recorder versions only Display Configuration Enable Cus...

Страница 20: ...t point values Alarm Status Active inactive status of all configured Alarms Trend View s A trend graph of PV1 PV2 or Differential or the Max Min value of the PV between samples Any active alarm s are...

Страница 21: ...s pfl for profiles is added automatically Caution Existing files folders with the same name will be over written Writing Configuration File The file is being written Caution Do not disconnect USB devi...

Страница 22: ...ations section for details Engineering Units w Select display units from C F K bar RH pH psi or none Decimal Point Position w Display resolution with 0 1 2 or 3 decimal places Temperature inputs are l...

Страница 23: ...h you conduct the High end calibration and required offset for calibration Calibration reminder Calibration reminder Enable or Disable Calibration reminder Calibration Reminder Date Set the date that...

Отзывы: