Page 118 of 146
198-1600-00 Rev F
B.1.12
Setup Command “s”:
@AA.a Sync character (@) and unit address, AA = Unit ID (0 to 99; 0 is a global ID),
a = Channel ID ( 0 to NUM_CHANNELS; 0 is a global channel)
s0
Command character and Type
– 0=read, 1=set, 2=activate (n/a), 3=ack,
4=nak
#21,
Number of fields character and number of fields after the comma, excluding
CRC.
100.0,
Forward Current Setting
– amps (not used when the output waveform type is
set to 2 (custom))
fi
12.25,
Forward Voltage settting
– volts (not used when the output waveform type is
set to 2 (custom))
fv
0,
Current Tolerance - Percent of Setting (0 to 100, 0 = disable tolerance
checks)
it
0,
Voltage Tolerance
– Percent of Setting (0 to 100, 0 = disable tolerance
checks)
vt
0,
XTC Control (0 = manual, 1 = RTC, 2 = ATC)
xc
1,
XTC Units (0=reserved, 1=ATC Amp Min, 2=ATC Amp Hr, 3=reserved,
4=RTC Min, 5=RTC Hr)
xn
0,
XTC Resolution (0=xxxx, 1=xxx.x, 2=xx.xx, 3=x.xxx)
xr
0,
XTC Preset (0 to 99999999, 0 to 9999999.9, 0 to 999999.99, or 0 to
99999.999, units and resolution are dependent on the xtc units and xtc
resolution specified in this command)
xs
0,
Current Ramp Preset (0
– 300.0 sec)
Irs
0,
Voltage Ramp Preset (0
– 300.0 sec)
vrs
0,
Pulse On Time (0
– 6.553 sec, 0 = DC) (only used when the output waveform
type is set to 1 (pulse))
pon
0,
Pulse Off Time (0
– 6.553 sec, 0 = DC) (only used when the output waveform
type is set to 1 (pulse mode))
poff
0,
Active Waveform Index (1 to 10) (only used when the output waveform type is
set to 2 (custom))
wv
0,
Home Link (1 to 40 = start link for custom wave form operation) (only used
when the output waveform type is set to 2 (custom))
hlnk
0,
Output Waveform Type (0 = DC, 1 = Standard Pulse, 2 = Custom)
wf
100.0,
Reverse Current Setting
– amps – positive value (not used when the output
waveform type is set to 2 (custom))
ri
12.25,
Reverse Voltage settting
– volts – positive value (not used when the output
waveform type is set to 2 (custom))
rv
0,
Reverse Pulse On Time (0
– 6.553 sec, 0 = DC) (only used when the output
waveform type is set to 1 (pulse))
rpon
0,
Reverse Pulse Off Time (0
– 6.553 sec, 0 = DC) (only used when the output
waveform type is set to 1 (pulse mode)
)
rpoff
0,
Forward Reading type (0 = Period Average, 1 = Real Time)
frd
0,
Reverse Reading type (0 = Period Average, 1 = Real Time)
rrd
CRC
CRC value in ascii decimal
crlf
Carriage return and Line feed (0x0D 0x0A)