Rev. 01/11
- 2.6 -
TFXL-X
The TFXL system calculates proper transducer spacing by utilizing
piping and liquid information entered by the user. This information is
entered via the
ULTRALINK™
software utility. The software utility
and a programming cable are required for programming TFXL
instruments.
NOTE:
Transducer spacing is calculated on “ideal” pipe. Ideal pipe
is almost never found so the transducer spacing distances should
be considered as starting points. An effective way to maximize
signal strength is to configure the display to show signal strength, fix
one transducer on the pipe and then starting at the calculated
spacing move the remaining transducer small distances forward and
back to find the maximum signal strength point.
PART 2 - TRANSDUCER INSTALLATION
Entering Pipe
and Liquid Data
Table 2.3
Transducer Mounting Modes
—
DTTS / DTTC
Size Frequency Transducer
Mounting
Mode
Size Frequency Transducer
Mounting
Mode
1/2
2 MHz
DTTSnP
V
1-1/4 2
MHz
DTTSnP
V
DTTSnC DTTSnC
DTTSnT DTTSnT
3/4
2 MHz
DTTSnP
1-1/2
2 MHz
DTTSnP
DTTSnC DTTSnC
DTTSnT DTTSnT
1
2 MHz
DTTSnP
2
1 MHz
DTTSnP
DTTSnC DTTSnC
DTTSnT
2 MHz
DTTSnT
NOTE:
DTTS transducer designation refers to both DTTS and DTTC transducer types
Содержание TFXL series
Страница 2: ......
Страница 10: ...Rev 01 11 1 8 TFXL X PART 1 TERMINOLOGY PC INTERFACE CABLE ...
Страница 23: ...Rev 01 11 2 3 TFXL X PART 2 TRANSDUCER INSTALLATION Table 2 1 Straight Pipe Requirements ...
Страница 52: ......
Страница 53: ...APPENDIX ...
Страница 54: ......
Страница 55: ......
Страница 69: ......