1.
Loosen screw (3) on the rocker arm.
2.
Adjust the hexagon nut (2), until the feeler gauge (1) can be
inserted and pulled out with noticeable resistance after the
screw (3) has been tightened.
1.
Install the valve cover (2) with a new gasket.
2.
Tighten the fastening screws (1) evenly.
3.
Assemble covering (1) and air filter cover (2).
4.
After a short test run check the valve cover for leaks.
8.7.3 Replacing the V-belt
Protective equipment:
n
Working clothes
n
Safety shoes
n
Protective gloves
1.
Park the machine safely
Chapter 6.4 ‘Parking the machine
in secured condition’ on page 57
2.
Allow the engine to cool down.
Adjusting the valve clearance
Fig. 63
Final work
Fig. 64
Fig. 65
Maintenance – Annually
DFP10D
77
Содержание DFP10D
Страница 6: ...Table of contents DFP10D 6...
Страница 7: ...1 Introduction Introduction DFP10D 7...
Страница 11: ...2 Technical data Technical data DFP10D 11...
Страница 15: ...3 Concerning your safety Concerning your safety DFP10D 15...
Страница 38: ...Concerning your safety Safety Components DFP10D 38...
Страница 39: ...4 Indicators and control elements Indicators and control elements DFP10D 39...
Страница 43: ...5 Checks prior to start up Checks prior to start up DFP10D 43...
Страница 50: ...Checks prior to start up Daily maintenance DFP10D 50...
Страница 51: ...6 Operation Operation DFP10D 51...
Страница 58: ...Operation Parking the machine in secured condition DFP10D 58...
Страница 59: ...7 Loading transporting the machine Loading transporting the machine DFP10D 59...
Страница 63: ...8 Maintenance Maintenance DFP10D 63...
Страница 88: ...Maintenance As required DFP10D 88...
Страница 89: ...9 Setting up refitting Setting up refitting DFP10D 89...
Страница 91: ...10 Troubleshooting Troubleshooting DFP10D 91...
Страница 95: ...11 Disposal Disposal DFP10D 95...
Страница 97: ......
Страница 98: ......