Installation, Operation and Service Manual
LKP Series
© 2016 DynAmp, LLC
Page 17
041749 K
TABLE 5.1
MEASURING HEAD RESISTANCE CHART
Measure Between
Leads:
Approx.
Value (
Ω
)
LKP-180
Approx.
Value (
Ω
)
LK-300
Approx.
Value (
Ω
)
LKP-400
Circuit
CABLE TO "A1" Quarter
of Head
15 & 23
20-24
15-18
11-15
Coil Circuit - Channel #1 A1
16 & 24
10-12
7.5-9
5.5-7.5
Coil Circuit - Channel #2
17 & 25
10-12
7.5-9
5.5-7.5
Coil Circuit - Channel #3
18 & 26
10-12
7.5-9
5.5-7.5
Coil Circuit - Channel #4
19 & 27
20-24
15-18
11-15
Coil Circuit - Channel #5 A1
10 & 12
750-1000
750-1000
750-1000
Hall Current - Channel #1 - 4
2 & 3
240-550
240-550
240-550
Hall Signal - Channel #1
4 & 5
240-550
240-550
240-550
Hall Signal - Channel #2
6 & 7
240-550
240-550
240-550
Hall Signal - Channel #3
8 & 9
240-550
240-550
240-550
Hall Signal - Channel #4
CABLE TO "A2" Quarter
of Head
39 & 30
20-24
15-18
11-15
Coil Circuit - Channel #5 A2
40 & 31
10-12
7.5-9
5.5-7.5
Coil Circuit - Channel #6
41 & 32
10-12
7.5-9
5.5-7.5
Coil Circuit - Channel #7
42 & 33
10-12
7.5-9
5.5-7.5
Coil Circuit - Channel #8
43 & 34
20-24
15-18
11-15
Coil Circuit - Channel #9 A2
45 & 47
750-1000
750-1000
750-1000
Hall Current - Channel #5 - 8
49 & 50
240-550
240-550
240-550
Hall Signal - Channel #5
51 & 52
240-550
240-550
240-550
Hall Signal - Channel #6
53 & 54
240-550
240-550
240-550
Hall Signal - Channel #7
55 & 56
240-550
240-550
240-550
Hall Signal - Channel #8