14
Models DCD-132 through DCD-225 Drive Ratings
the Basic Model DCD drive includes a TEFC AC
induction motor flange mounted to an eddy-current
clutch. Table 2-1 lists units requiring a 230/460 VAC,
3 phase, 60
Hz
, 1.15 SF input.
NEMA design B,
Class F insulation is used in all motors.
60 Hz. Drives
Table 2-1
HP
Speed
Range
RPM
TEFC
Model
Number
TEFC
Motor
Frame
Size
3
1630-0
DCD-132030-4141
145TC
5
1500-0
DCD-132050-4141
145TC
5
3300-0
DCD-132050-4121
182TC
7.5
3300-50
DCD-132075-4121
184TC
7.5 1660-350
1680-50
DCD-132075-4141
DCD-160075-4141
213TC
213TC
10
3250-0
1580-0
DCD-132100-4121
DCD-160100-4141
215TC
215TC
15
3300-0
1550-340
DCD-160150-4121
DCD-160150-4141
254TC
254TC
20
3250-0
1615-145
DCD-160200-4121
DCD-160200-4141
256TC
256TC
25
3250-640
DCD-160250-4121
284TSC
All drives have 100% rated motor torque continuously
available over the speed range shown in the tables
below.