3101C Gen II MANUAL
11/17
INSTALLATION INSTRUCTIONS
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
3101C
DELAYED
EGRESS LOCK
(GENERATION II)
Inspect the door frame and determine if an angle bracket, spacer or filler plate will be required for installation. The
lock will require a 2-9/16” wide header stop for a suitable mounting surface.
*These items are available from DynaLock.
MOUNTING CONSIDERATIONS
NORMAL
MOUNTING
*FILLER PLATE
REQUIRED
*ANGLE BRACKET
REQUIRED
USING THE TEMPLATE
Fold the template on the dotted line to form a 90 degree
angle. Scoring the template with a straight edge and a
screwdriver will make it fold easier.
With the door in the closed and latched position place
the template against the header and door with one edge
against the vertical strike jamb and tape in place.
Transfer all hole locations to both the door and header
with a center punch, then remove the template from
the door.
Referring to the template drill two 1/8” dia. lock
mounting holes and one 9/16” dia. wiring hole in the
top of the frame, at the transferred locations.
1.
2.
3.
4.
Drill the remaining transferred holes in the face of the door to accept the Armature Mounting Plate
Assembly:
a. Four 1/8” dia. mounting screw holes, 1” deep.
b. One 3/8” dia. armature screw clearance hole, 3/8” deep.
c. One 5/16” dia. adjustment wheel screw clearance hole, 1/4” deep.
5.
2-9/16”
2-9/16”
*SPACER PLATE
REQUIRED
9/16" DIA. WIRING HOLE
1/8" DIA. DRILL
PLACE AGAINST HEADER
FOLD ON DOTTED LINE
1/4" DIA. ARMATURE GUIDE PIN
HOLES 9/16" DEEP (2 REQ'D.)
1/8" DIA. DRILL
(4 PLACES)
PLACE AGAINST JAMB
OPPOSITE HINGES FOR
L.H.R. DOOR INSTALLATION
PLACE AGAINST JAMB
OPPOSITE HINGES FOR
R.H.R. DOOR INSTALLATION
#3101-B SERIES
ELECTROMAGNETIC LOCK
11/32" DIA. ARMATURE SCREW
CLEARANCE HOLE 1" DEEP
CARDBOARD
TEMPLATE
HINGE SIDE
OF DOOR