Page 13
3101C Gen II MANUAL
11/17
INSTALLATION INSTRUCTIONS
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
3101C
DELAYED
EGRESS LOCK
(GENERATION II)
Observe polarity when re-connecting the J5, J7, J8 harness connectors. Orient these connectors with
respect to harness wire colors as follows:
J5
WHT GRN RED BLK
**J10 WHT BLK BLU
J7
WHT BLK BLU
J8
GRN WHT RED
FACTORY WIRING
DYNASTAT
HARNESS
(2 COND.)
DSM OPTION
HARNESS
(3 COND.)
3101C SENSOR COVER
ASSEMBLY
SENSOR
HARNESS
(4 COND.)
COIL
HARNESS
(4 COND.
)
KEYSWITCH HARNESS (3 COND.)
ON-BOARD KEYSWITCH
DSM
OPTION
SENSOR
LOCK COIL ASSEMBLY
3101C CIRCUIT BOARD
Harness connectors J3 and J6 are not polarity sensitive.
Harnesses J6 and J8 are only present if the 3101C is equipped with the DYN - Dynastat Force Sensor
and/or DSM - Door Status Switch Options.
1.
2.
3.
NOTES:
BPM BYPASS MONITOR
OPTION (2 YELLOW COND.)
MAINTAINED - N.O., 4A@125V
3101A SERIES
LEGACY SENSOR
(OPTIONAL)
**Note:
J10 is normally not-used. It is specifically intended to allow interfacing the 3101C Circuit Board to
a 3101A Series legacy sensor cover assembly, when necessary.