3.4. IMPORTANT SAFETY PRECAUTIONS IN REGARD TO ELECTROSTATIC
CHARGES GENERATION
When the vacuum cleaner system is used as recommended in this manual it has been
determined that no significant or continuous electrostatic charge accumulation, which could act
as a potential ignition source, can occur.
Nevertheless, it is recommended for safe use not to perform any specific action on the insulating
items assembled on the vacuum cleaner system, such as a continuous and intense manual
rubbing, which could lead to a significant electrostatic charge accumulation.
The above instructions are to be observed particularly in regard to the plastic wheel covers.
4.0 COMPRESSED AIR REQUIREMENTS
IMPORTANT:
The compressed air has to be clean, dry and oil free to prevent
blockage of the pneumatic system.
Minimum diameter of air supply hose and
fittings
0.5" (12.7mm)
Input air pressure for ideal performance
80 PSI (5.5. bars)
Input air volume for ideal performance
35-45 CFM (59.5-76.5 cu. meters / hour)
Minimum compressor size
15 HP
IMPORTANT:
Do not downsize the compressed air fittings or air supply line.
Downsizing the fittings will result in a reduction of the vacuum
cleaner’s performance.
IMPORTANT:
Brass (or stainless steel) fittings are required to ensure spark free
operation and to ensure ground continuity between vacuum
cleaner and the compressed air supply.