Page
2
of
23
ROUTINE MAINTENANCE FOR IMMERSION SEPARATOR "WET MIX"
MODEL ATEX-10A IT-40L CFE HEPA
•
This unit must be filled with water at all times during operation.
•
This unit must be filled up to the liquid level indicator line shown on the recovery tank.
•
Do not exceed the below recommended maximum dust recovery capacity.
Water required
Max. dust recovery capacity
3.25 gallons / 12.3 liters
Recovery bag
Tank
0.80 gallon / 3 liters 1 gallon / 3.8 liters
We recommend proceeding with the following maintenance after each use and after a maximum of 8
hours of consecutive use:
•
Drain the water by opening up the manifold drain valve
•
Once drained the unit must be disconnected from its power source
•
Disengage the latches and remove the power head from the recovery tank
•
Discard all recovered material from inside of the recovery tank.
•
Thoroughly clean all parts of the unit including the suction hose.
•
Once unit is clean install the conductive recovery bag inside the recovery drum and fill it of clean
water.
In addition: After 5 hours of consecutive use turn off the vacuum cleaner system and verify the water level
COALESCING FILTER ELEMENT (CFE)
Verify if the CFE needs to be replaced as part of routine maintenance.
Содержание 61496