background image

DV-M2 1/2013 

 

DV-M2 

Industrial Vacuum Cleaner 

Operating and Maintenance Instructions 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Goodway Technologies Corporation 

420 West Avenue 

Stamford, CT  06902-6384  USA 

Phone (203) 359-4708 

Toll Free 1-800-333-7467 

Fax (203) 359-9601 

Internet:  http://www.goodway.com 

E-Mail:  [email protected] 

 

 

Содержание DV-M2

Страница 1: ...Cleaner Operating and Maintenance Instructions Goodway Technologies Corporation 420 West Avenue Stamford CT 06902 6384 USA Phone 203 359 4708 Toll Free 1 800 333 7467 Fax 203 359 9601 Internet http www goodway com E Mail goodway goodway com ...

Страница 2: ...Maintenance Instructions By carefully following the instructions you will obtain years of trouble free service from this product Please pay particular attention to the safety instructions and exercise caution when using this machine We are here to serve you For Sales call 1 800 333 7467 For Service call 1 800 370 2855 Goodway Technologies Corp Goodway reserves the right to improve products contact...

Страница 3: ... cleaner IMPORTANT SAFETY INSTRUCTION READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM CLEANER WARNING To reduce the risk of fire electric shock or injury 1 Do not leave appliance when plugged in Disconnect unit from power when not in use or before servicing WARNING To reduce the risk of electric shock Do not use outdoors or on wet surfaces 2 Use only as described in this manual Use only manufacture...

Страница 4: ... Do not use with any opening blocked keep free of dust lint hair and anything that may reduce airflow 9 Keep hair loose clothing fingers and all parts of body away from openings and moving parts 10 Turn off all controls before unplugging 11 Use extra careful when cleaning stairs 12 Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present 13 ...

Страница 5: ...with the appliance if it will not fit the outlet have a proper outlet installed by a qualified electrician This appliance is for use on a nominal 120 volt circuit and has a grounding attachment plug that looks like the plug illustrated in sketch A below A temporary adaptor that looks like the adaptor illustrated in sketches B and C may be used to connect this plug to a two pole receptacle as shown...

Страница 6: ... shaker turn the motor off and vigorously move the black handle up and down dislodging particles from the filter To Empty Debris Collection Tank WARNING As the filter will be dirty protective eyewear breathing mask and gloves must be worn To empty the debris container turn off the vacuum motor and disconnect the plug from the power socket Turn the two levers on the side of the vacuum cleaner fully...

Страница 7: ...r the vacuum cleaner see figure 3 Release the two retainers that hold the motor head in place and lift the motor head off the vacuum Rest this on a flat surface being careful not to damage the power cable 4 Remove the filter container 5 Take the filter out by loosening the filter clamps 6 Remove the knots and take out the pocket filter Fit the new filter and put everything back in place locking th...

Страница 8: ...forated filter Replace the filter 3 Filter unsuitable for type of job Fit a suitable filter for the type of material to be vacuumed Contact Goodway Technologies Corporation s Customer Service at 800 370 2855 if problems are not resolved Technical details Motor s Twin Motor Power 2 7 HP total Input power 15 amps 115V 50 60 Hz AC Power Supply Cord 30 14 3 Static Water Lift 90 Air Displacement 224 CF...

Страница 9: ...DV M2 1 2013 9 Body Assembly Drawing ...

Страница 10: ...Zig zag spring 9 AR 2415 1 Die cast deflector 10 AR 2002 2 Hook fastener 11 AR 2008 1 Filter shaker lever knob 12 AR 2066 1 Bellows 13 AR 2065 1 Filter shaker flange 14 AR 3489 1 Metallic filter shaker lever 15 AR 3490 1 Metallic filter chamber 16 AR 2418 1 Die cast union pawl 17 AR 2417 1 Die cast union spring 18 AR 2416 1 Die cast union pin 19 AR 2413 1 Die cast union 20 AR 3491 1 Metallic die c...

Страница 11: ...DV M2 1 2013 11 Trolley Assembly Drawing ...

Страница 12: ...ns 8 AR 3500 1 Metallic trolley frame 9 AR 3513 2 Socket cap screw for slider pawl 10 AR 2363 2 Slider pawl 11 AR 3502 1 Accessory basket 12 AR 3503 1 Right hand lifting release rod 13 AR 3504 1 Left hand lifting release rod 14 AR 3505 2 Nylon spacer 15 AR 3506 2 Countersunk screw for rotation fulcrum 16 AR 3507 2 Rotation closing washer 17 AR 3508 2 Aluminum body 18 AR 3509 2 Lever mechanism rota...

Страница 13: ...DV M2 1 2013 13 Motor Head Assembly Drawing ...

Страница 14: ...1 Vacuum meter 15 AR 3314 1 Air pipe connection piece 16 AR 3525 1 Socket 17 AR 3527 2 Switch 18 AR 2496 4 Fuses 19 AR 3529 1 Instrument panel 20 AR 2038 2 Cooling rings 21 AR 3528 1 Seal for instrument panel 22 AR 3530 1 Pipe 23 AR 3531 1 Female T union 24 AR 3532 1 M F spacer 25 AR 3533 1 F F spacer 26 AR 3534 1 Motor stopper 27 AR 3535 1 Motor stopper sound proofing set 5 pcs 28 AA 2616 2 Bypas...

Страница 15: ...istributes a complete line of Tube Pipe Cleaning Systems Duct Cleaning Systems Vacuums Floor Machines Hi Pressure Washers and other maintenance related equipment GOODWAY TECHNOLOGIES CORPORATION 420 WEST AVENUE STAMFORD CT 06902 USA Tel 203 359 4708 Toll Free Tel 800 243 7932 Fax 203 359 9601 Toll Free Fax 800 359 9625 goodway goodway com www goodway com ...