Tridak® Model 1001 Syringe Filling System User Guide
3.
Ensure the Luer Tip Cap is installed and tightened onto the Luer Tip.
4.
Disconnect the Material Reservoir Pressure Supply from the Material Reservoir Air Inlet.
5.
Connect a Compressed Air Supply (max 90 psi) to the System Pressure Inlet.
6.
Set the Air Regulator to 0 psi.
7.
Connect the Material Reservoir Pressure Supply to the Material Reservoir Air Inlet.
8.
Set the Air Regulator to 10 psi starting pressure.
9.
Check for any material leaks occurring at the Luer Tip or at the Material Cartridge and depressurize
the system if any leaks are present.
Depressurizing the System
1.
Ensure the Luer Tip Cap is installed and tightened onto the Luer Tip.
2.
Set the Air Regulator to 0 psi.
3.
Disconnect the Material Reservoir Pressure Supply from the Material Reservoir Air Inlet.
4.
Disconnect the Compressed Air Supply from the System Pressure Inlet.
Adjusting the Syringe Rest
Use the adjustable syringe rest to support the syringe during the fill cycle, and ensure the syringe is centered
around the fill stop switch. (Figure 10)
1.
Slightly loosen the Syringe Rest Base Screw.
2.
Slide the Syringe Rest Base along the fixture base slot channel until the Syringe Rest is close to the
syringe flange.
3.
Tighten the Syringe Base Screw.
4.
Loosen the Syringe Rest Set Screw.
5.
Lift the Syringe Rest until the v-block is fully supporting the syringe.
6.
Tighten the Syringe Rest Set Screw.
Setting the Fill Amount for the Syringe Size
For the required syringe size, use the scale to set the fill volume by adjusting the syringe fill stop to the desired
location.
1.
Disconnect the Compressed Air Supply from the Material Reservoir.
2.
Connect the incoming Air Supply Line to the Compressed Airline Inlet.
3.
By hand, set the Syringe Piston or Plunger to the desired fill/mL volume.