Dymax BlueWave® LED Flood System User Guide
protection/training for operators. No infrared radiation is produced by these LED systems, so surface
temperatures will be lower than with conventional lamp systems. Empirical testing should be used to verify
the exact temperature rise in each application.
Bright, Visible Light
The bright, visible light energy emitted by curing systems can cause eye strain if proper eye protection or
shielding is not used. The proper use of tinted eye protection and/or opaque/tinted shielding can be utilized to
reduce eye strain and address this concern.
Product Overview
Description of the
BlueWave LED Flood System
The
BlueWave LED Flood System
is a high-intensity unit used for curing light-curable materials. The unit is
designed to be integrated into a larger system, such as an automated manufacturing system, or with a light
shielding enclosure to create a bench-top curing station.
The
BlueWave LED Flood System
consists of two main components: an LED flood array and a power supply
that contains the user interface. Dymax offers three different wavelength LED flood arrays: VisiCure® (405
nm), PrimeCure
™
(385 nm), and RediCure
™
(365 nm). Only one LED flood array can be connected to the
power supply at a time via the interconnect cable. The power supply is designed to identify the type of LED
array that is connected so the power supply can be used with any of the three LED flood arrays.
The unit can be operated in timed or manual modes and features an intensity adjustment, allowing the output
intensity level to be adjusted from 10 to 100% to meet process and adhesive requirements. LED technology
within the
BlueWave LED Flood System
allows for instant on/off activation without the need for a warm-up
period, but is also rated for continuous operation.
Fans in the LED flood power supply and array provide cooling and must not be covered or blocked. Fan Filters
must be maintained regularly to ensure reliable operation.
Thermal sensors in the LED flood power supply and array shut the unit down to protect the components if the
internal temperature exceeds maximum limits.
WARNING!
If you block the air flow from the LED flood array or the power supply vents,
equipment damage and malfunction can result. To prevent damage and malfunction, ensure 1"
[2.54 cm] of clearance is provided around the power supply and at least 6" [15.24 cm] of clearance
is provided around the cooling fan inlets and outlet to allow the free flow of air.
AVERTISSEMENT!
Vous pouvez endommager l'équipement ou avoir des difficultés avec
l'utilisation si vous bloquez la ventilation pour les lumières LED ou l'alimentation électrique. Pour
éviter la détérioration ou le mauvais fonctionnement du système, veuillez vous assurer que
l'installation offre un retrait de 1'' [2.54 cm] autour de l'alimentation électrique et au moins 6''
[15.24 cm] de retrait avec la sortie de ventilation et assurez-vous qu'il y a une bonne circulation
d'air.